Abstract
Generator adalah salah satu komponen utama dalam PLTU yang berfungsi untuk mengkonversi energi mekanik menjadi energi listrik. Agar daya listrik yang dikirim ke konsumen bisa maksimal maka generator harus memiliki efisiensi yang tinggi. Efisiensi generator merupakan suatu perbandingan antara daya keluaran (Pout) dan daya masukan (Pin). Kemampuan daya masukan generator dapat dihitung dengan mejumlahkan daya keluaran dengan total daya yang terbuang atau rugi-rugi total pada generator. Rugi-rugi pada generator umumnya terdiri dari rugi-rugi belitan, rugi-rugi inti besi, rugi-rugi mekanik dan rugi-rugi sasar. Semakin besar rugi-rugi total generator maka efisiensinya akan cenderung turun. Berdasarkan hasil analisa tentang efisiensi generator sinkron, efisiensi yang didapat dari tanggal 01 Januari 2018 sampai 05 Januari 2018 disini terlihat bahwa rata-rata efisiensi perhari pada generator tersebut berkisar antara 98-99 %. Jika ditinjau dari perhitungan dan grafik yang didapat dari analisa, efisiensi generator sangat dipengaruhi oleh beban. Jika semakin besar daya keluarannya atau daya yang terpakai maka tingkat efisiensi generator akan semakin tinggi.
Generator is one of the main components in PLTU used to convert mechanical energy into electrical energy. The generator must have high efficiency so that the electric power delivered to the consumer can be maximized. Generator efficiency is a comparison between output power (Pout) and input power (Pin). The generator input power can be calculated by summing the output power by the total wasted power or the total losses in the generator. Generator losses generally consist of winding losses, iron core losses, mechanical losses and stray losses. The greater the total losses generator then the efficiency will tend to go down. Based on the analysis of synchronous generator efficiency, the efficiency obtained from 01 January 2018 to 05 January 2018 shows that the average efficiency per day on the generator ranges between 98-99%. In terms of calculations and graphs obtained from the analysis, generator efficiency is greatly influenced by load. The greater the power output or power used the generator efficiency will be higher.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | generator, efisiensi, daya, rugi-rugi generator, efficiency, power, losses |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |