ANALISIS SUSUT UMUR TRANSFORMATOR DISTRIBUSI AKIBAT PEMBEBANAN DI PT. PLN (PERSERO) UP3 TANJUNG PRIOK

Julian, Kevin and Isworo, lakso (2019) ANALISIS SUSUT UMUR TRANSFORMATOR DISTRIBUSI AKIBAT PEMBEBANAN DI PT. PLN (PERSERO) UP3 TANJUNG PRIOK. Diploma thesis, ITPLN.

[thumbnail of Kevin Julian (2014-11-269).pdf] Text
Kevin Julian (2014-11-269).pdf
Restricted to Registered users only

Download (1MB)

Abstract

Transformator distribusi merupakan salah satu komponen utama pada suatu sistem distribusi tenaga listrik ke pelanggan. Tanpa adanya Trafo distribusi pelanggan tidak dapat menggunakan energi listrik secara langsung mengingat tegangan operasi distribusi adalah 20 KV atau disebut jaringan tegangan menengah sehinggal diperlukan Transformator distribusi step down untuk menurukan tegangan 20 KV tersebut menjadi tegangan rendah 220/380 Volt. Oleh karena itu, diusahakan agar peralatan ini berusia panjang dan dapat lebih lama dipergunakan, maka pemasangan dan pemeliharaan transformator harus sesuai dengan standar yang ditetapkan. International Electrotechnical Commission (IEC) 354 tahun 1972 menyatakan apabila transformator dibebani stabil pada daya pengenalnya dengan kondisi suhu sekitar 20℃, suhu hot spot transformator akan mencapai 98℃ dan umur transformator akan mencapai 20,55 tahun atau 7500 hari. Suhu sekitar kota Jakarta Utara rata-rata 30℃. Hasil yang didapat menyatakan bahwa terjadi susut umur relatif sebesar 8,1% - 14% pada 3 trafo yang digunakan sebagai penelitian bila beban sesuai dengan pengukuran (71,83% % - 81,6%%). Sebaliknya bila mengikuti pertumbuhan beban, trafo dibebani terus menerus sebesar 100% daya rated maka susut umur relatif menjadi 317%. Dari sini dapat disimpulkan bahwa pembebanan 80% merupakan strategi yang cukup baik ditinjau dari segi umur trafo. Pembebanan tersebut juga dapat mengantisipasi bila terjadi pembebanan lebih yang sifatnya temporer.

Distribution transformer is one of the main components in a system of distributing electricity to costumers. Without the distribution transformer, the costumer cannot use electricity directly considering the distribution operating voltage is 20 KV or called medium voltage network. It needs a step down distribution transformer to reduce the voltage of 20 KV to a low voltage of 220/380 KV. That is why, the tools is must to be in a long age dan can be use for a long time. then the installation and maintenance of the transformer must be in accordance with established standards. Electrotechnical Commission (IEC) 354 claim if a transformer get a stable load on it’s identification power with ambient temperature 20℃, transformer hot spot temperature will reach 98℃ and it’s lifetime became 20,55 years or 7500 days. Daily average ambient temperature in Jakarta is 30℃. The result obtained state that there was a relative age 8,1% to 14% of the 3 transformers used ad research if the load was in accordance with measurement (71,83 – 81,6%). Conversely, if you follow the growth of the load, the transformer is burdened continously by 100% rated power, then the relative shrinkage to 317%. From this it can be conclude that the loading of 80% is a pretty good strategy in terms of the age of the transformer. This loading can also be anticipated if there is a temporary overloading.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: transformator distribusi, susut umur, beban, suhu sekitar distribution transformer, loss of life, loading, ambient temperature
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 10 Nov 2025 06:42
Last Modified: 10 Nov 2025 06:42
URI: https://repository.itpln.ac.id/id/eprint/3653