ANALISIS KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG BAMBU GIS 150/20 KV 60 MVA KEBON JERUK

Pratama, Wisnu and Hariyanto, Agung (2019) ANALISIS KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG BAMBU GIS 150/20 KV 60 MVA KEBON JERUK. Diploma thesis, ITPLN.

[thumbnail of Skripsi Fix.pdf] Text
Skripsi Fix.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dalam pengoperasian transformator daya pada suatu gardu induk tidak pernah lepas dari gangguan, baik gangguan hubung singkat fasa-fasa maupun fasa ke tanah, sama halnya yang terjadi pada GIS Kabon Jeruk tepatnya pada penyulang Bambu. Gangguan yang terjadi dapat menimbulkan kerugian di pihak konsumen. Oleh karena itu diperlukan koordinasi peralatan pengaman pada sisi outgoing dan incoming trafo sehingga gangguan dapat diusahakan menjadi sekecil mungkin. Rele arus lebih digunakan untuk mendeteksi hubungan singkat antar fasa dan rele gangguan tanah untuk mendeteksi hubungan singkat fasa ke tanah.. Hasil yang didapat pada perhitungan yaitu untuk rele arus lebih pada sisi outgoing 20 kV memiliki nilai TMS = 0,222, sedangkan untuk rele gangguan tanah pada sisi penyulang 20 kV memiliki nlai TMS = 0,108, kemudian untuk rele arus lebih pada sisi incoming 20 kV memiliki nilai TMS = 0,202, sedangkan untuk rele gangguan tanah pada sisi incoming 20 kV memiliki nilai TMS = 0,234.

In the operation of a power transformer at a substation it is never separated from interference, both phase and phase to ground short circuit disturbances, as well as what happened to GIS Kabon Jeruk precisely on Bamboo feeders. Interference that occurs can cause losses on the part of the consumer. Therefore, it is necessary to coordinate protection instrument on the outgoing dan incoming of transformer so that interference can be minimized as small as possible. Over current relay is preffered to be used to detect short-circuit between two phases; and ground fault relay is preffered to be used to detect short circuit a phase and neutral.The results obtained on the calculation is for over current relay on the side of the feeder 20 kV has a value of TMS = 0.222, while for ground fault relay on the side of the feeder 20 kV has nlai TMS = 0.108, then for over current relay on the incoming side of 20 kV has a TMS value = 0.202, while for ground fault relay on the incoming side of 20 kV has a value of TMS = 0.234.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: arus hubung singkat,rele arus lebih,rele gangguan tanah short circuit current,over current relay,ground fault relay
Subjects: Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 10 Nov 2025 07:43
Last Modified: 10 Nov 2025 07:43
URI: https://repository.itpln.ac.id/id/eprint/3665

Actions (login required)

View Item
View Item