EVALUASI PENTANAHAN GARDU INDUK PLUMPANG TERHADAP TEGANGAN LANGKAH AKIBAT SAMBARAN PETIR

Ivanky, Gilang Rahmad and Soewono, Soetjipto (2019) EVALUASI PENTANAHAN GARDU INDUK PLUMPANG TERHADAP TEGANGAN LANGKAH AKIBAT SAMBARAN PETIR. Diploma thesis, ITPLN.

[thumbnail of GILANG RAHMAD IVANKY 2014-11-236.pdf] Text
GILANG RAHMAD IVANKY 2014-11-236.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Gardu induk sebagai salah satu bagian sistem tenaga listrik yang berperan dalam penyaluran tenaga listrik dari pusat pembangkit menuju beban, sehingga kondisinya harus dipastikan aman. Namun gardu induk memiliki potensi mengalami gangguan akibat sambaran petir yang menyambar saluran pada Gardu Induk yang dapat membahayakan kondisi peralatan dan manusia di sekitarnya, salah satu yang membahayakan manusia adalah tegangan langkah yang tidak mampu di terima manusia maka Gardu Induk Plumpang memakai sistem pembumian Grid sebagai pelindungnya. Untuk mengevaluasi pentanahan gardu induk menggunakan metode kualitatif yaitu mengolah datadata dengan rumus untuk mendapat hasil penelitian. Dari hasil perhitungan di peroleh tahanan pentanahan pada gardu induk plumpang sebesar 0,11Ω. Sedangkan dari hasil pengkuran di lapangan di peroleh nilai 0,13.Untuk nilai tegangan langkah yang terbesar akibat sambaran petir pada sitem pentanahan grid sebesar 370,7099224 V. Sedangkan nilai tegangan langkah terbesar akibat sambaran petir pada pentanahan tanpa menggunakan grid sebesar 501,8916 V

The substation as one part of the electric power system that plays a role in the distribution of electric power from the power plant to the load, so the conditions must be ensured safe. However, the main substation has the potential to experience interference due to lightning strikes the channel on the substation which can endanger the condition of the equipment and humans around it, one that endangers humans is a voltage step that cannot be received by humans, so the Plumpang substation uses the Grid earthing system as its protector . To evaluate grounding substations using qualitative methods, namely processing data with a formula to get the results of research. From the results of calculations obtained grounding prisoners at the main substation plumpang of 0.11Ω. While from the results of measurements in the field obtained a value of 0.13. For the largest step stress value due to lightning strikes on the grid ground system of 370.7099224 V. While the value of the largest step stress due to lightning strikes on the ground without using a grid of 501.8916 V

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Gardu induk, pentanahan grid, Tahanan pentanahan, Tegangan Langkah, Sambaran petir substation, Grounding grid , Earth arrestees, Step Voltage,Lightning Strike
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 10 Nov 2025 08:29
Last Modified: 10 Nov 2025 08:29
URI: https://repository.itpln.ac.id/id/eprint/3673