Rulin, Vella Marta and Hajar, Ibnu (2018) ANALISA SETTING RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA TRAFO 150KV/20KV DI GARDU INDUK SOLOK. Diploma thesis, ITPLN.
VELLA MARTA RULIN, 201411225.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Tenaga listrik merupakan salah satu kebutuhan pokok masyarakat saat ini, maka untuk menjamin kualitas pelayanan diperlukan listrik yang andal. Maka salah satu usaha yang dapat dilakukan adalah dengan meminimalisir gangguan yang terjadi dalam sistem tenaga listrik. Dengan demikian dibutuhkan suatu perencanaan perhitungan serta analisa dari perhitungan arus hubung singkat agar terciptanya koordinasi proteksi Over Current Relay (OCR) dan Groung Fault Relay (GFR) yang baik di sisi penyulang, incoming 20 kV dan sisi 150 kV. OCR merupakan peralatan tenaga listrik yang melindungi dari gangguan arus lebih. GFR merupakan peralatan tenaga listrik yang melindungi dari adanya gangguan fasa tanah. Pada skripsi ini menggunaka metode kuantitatif, dimana data yang dikumpulkan berupa angka, pengolahan daa menggunakan rumus – rumus dan hasilnya dalam bentuk angka. Koordinasi setting OCR dan GFR untuk gangguan fasa – fasa maupun fasa – tanah dapat dilihat bahwa waktu kerja relai di sisi penyulang lebih cepat dibanding waktu kerja di sisi incoming dan sisi 150kV. Begitu juga semakin besar arus gangguan maka waktu kerja relai semakin cepat dan begitupun sebaliknya. Semakin jauh jarak lokasi gangguan maka semakin lama waktu kerja relai di penyulang dan waktu kerja relai di incoming serta sisi 150kV.
Electric power is one of the basic needs of the community at this time, so to guarantee the quality of service, reliable electricity is needed. So one of the efforts that can be done is to minimize the disruption that occurs in the electric power system. Thus, a calculation and analysis planning from the calculation of short circuit current is needed to create coordination of Over Current Relay (OCR) protection and Groung Fault Relay (GFR) both on the feeder side, incoming 20 kV and 150 kV side. OCR is an electrical power device that protects against overcurrent interference. GFR is an electric power device that protects against ground phase disturbances. This thesis uses a quantitative method, where data collected in the form of numbers, processing and using formulas and results in the form of numbers. Coordination of OCR and GFR settings for ground and phase - ground disturbances can be seen that the relay working time on the feeder side is faster than the working time on the incoming and 150kV sides. Likewise, the greater the flow of disturbances, the more time the relay's working time and vice versa. The farther the distance of the fault location, the longer the relay work time will be and the relay work time and the 150kV side.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Gangguan, Proteksi, OCR, GFR Interference, Protection, OCR, GFR |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Nov 2025 04:07 |
| Last Modified: | 11 Nov 2025 04:07 |
| URI: | https://repository.itpln.ac.id/id/eprint/3710 |