ANALISIS KOORDINASI PROTEKSI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG KALA2 DAN PENYULANG ADIK DENGAN INCOMING TRANSFORMATOR DAYA 3 150/20 kV 60 MVA DI GARDU INDUK GANDUL

KURNIADI, AGUNG and Rusli, Muhammad (2018) ANALISIS KOORDINASI PROTEKSI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG KALA2 DAN PENYULANG ADIK DENGAN INCOMING TRANSFORMATOR DAYA 3 150/20 kV 60 MVA DI GARDU INDUK GANDUL. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI (fix) Agung 12.pdf] Text
SKRIPSI (fix) Agung 12.pdf
Restricted to Registered users only

Download (4MB)

Abstract

Transformator daya merupakan salah satu komponen penting dalam penyaluran sistem ketenagalistrikan. Untuk itu keandalan dari transformator daya haruslah dijaga dalam kondisi yang baik. Karenanya proteksi pada trafo harus di koordinasikan agar tidak terjadi kesalahan dalam mendeteksi gangguan (efektif dan selektif). Penelitian ini menggunakan metode kuantitatif dengan melakukan perhitungan dari data yang di dapatkan. Dari perhitungan penyetelan rele OCR dan GFR untuk sisi incoming dan penyulang transformator daya 3 GI Gandul didapatkan penyetelan TMS untuk rele sisi penyulang pada penyulang kala2 dengan rele OCR sebesar 0.20598 dan rele GFR sebesar 0.11054 dan untuk rele pada penyulang adik dengan rele OCR sebesar 0.19251 serta rele GFR sebesar 0.11165. Penyetelan TMS untuk rele di sisi incoming trafo dengan setelan OCR pada penyulang kala2 sebesar 0.19568 dan untuk rele GFR sebesar 0.28146 serta untuk penyulang adik dengan rele OCR sebesar 0.19569 dan rele GFR sebesar 0.28405. Sehingga dengan penyetelan yang didapat diharapkan mampu meningkatkan keandalan proteksi pada Gardu Induk Gandul

Power transformers are one of the important components in the distribution of the electricity system. For this reason the reliability of the power transformer must be maintained in good condition. Therefore the protection of the transformer must be coordinated so that there is no error in detecting interference (effective and selective). This study uses quantitative methods by calculating the data obtained. From the calculation of OCR and GFR relay settings for the incoming and feeder side of the power transformer 3, Gandul substastion obtained TMS adjustment for feeder side relay on the feeder with OCR relay at 0.20598 and GFR relay at 0.11054 and for relay on sister feeder with OCR relay at 0.19251 and relay GFR of 0.11165. Adjusting the TMS for relay on the side of the incoming transformer with the OCR setting on the feeder at the time of 0.19568 and for the GFR relay of 0.28146 and for the brother feeder with OCR relay of 0.19569 and GFR relay of 0.28405. So that the obtained settings are expected to be able to increase the reliability of protection at Gandul Substation

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator daya, Rele OCR, Rele GFR, Incoming, Penyulang Power Transformer, OCR Relay, GFR Relay, Incoming, Outgoing
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 11 Nov 2025 04:13
Last Modified: 11 Nov 2025 04:13