Febriansyah, Idfi and Koerniawan, Tony (2018) STUDI PENGARUH PEMBEBANAN DAN SUHU TERHADAP SUSUT UMUR TRANSFORMATOR TENAGA 60 MVA DI GARDU INDUK GANDUL 150/20 kV UNIT 3. Diploma thesis, ITPLN.
201411211.pdf
Restricted to Registered users only
Download (9MB)
Abstract
Gardu induk Gandul merupakan objek vital negara, sehingga diperlukan pengawasan khusus pada setiap peralatan yang ada. Umur transformator dapat berkurang akibat beberapa hal. Salah satu penyebab berkurangnya umur penggunaan transformator adalah pembebanan. Tujuan dari penelitian ini untuk menganalisis pengaruh pembebanan dan suhu sekitar terhadap susut umur transformator unit 3 di GI Gandul, sehingga dapat mengetahui sisa umur transformator yang sedang beroperasi. Penelitian ini menggunakan metode penelitian deskriptif. Adapun sumber data yang digunakan merupan data-data pembebanan dan suhu sekitar pada transformator unit 3 GI Gandul yang diperoleh dari PT. PLN (Persero) P2B Jawa Bali. Data akan dianalisa berdasarkan dengan thermal ageing of insulation dan loss of life calculation. Berdasarkan analisa data yang dilakukan, diperoleh kesimpulan bahwa setiap kenaikan suhu hot spot akan semakin besar laju susut umur pada transformator maka akan mengakibatkan umur pakai transformator semakin singkat. Berdasarkan data pembebanan tahun 2017 susut umur trafo tenaga Unit 3 GI Gandul dengan pembebanan maksimum tanggal 12 Mei 2017 menghasilkan susut umur 23,560% dengan perkiraan sisa umur sebesar 34,55 tahun. Hasil penelitian untuk pembebanan konstan pada pembebanan 80% diperoleh susut umur minimal yaitu 29%, pada pembebanan 90% diperoleh susut umur 103,37% dan pada pembebanan 100% diperoleh susut umur 416,6%. Besarnya beban pada transformator unit 3 GI Gandul adalah 81,8% yang untuk dapat menggunakan transformator selama 100% usia pakai.
Gandul substation is a vital object, so special supervision is required for every equipment available. The life of the transformer can be reduced due to several things. One of the causes of reduced use of the transformer is the load. The purpose of the research was to learn about loading and temperature on the composition of the transformer unit 3 in GI Gandul, can determine the age of the transformer in operation. This research uses descriptive research method. The source of the data used is the loading data and ambient temperature of the transformer unit 3 GI Gandul obtained from PT. PLN (Persero) P2B Java and Bali. The source will be analyzed based on thermal aging of insulation and loss of life calculation. Based on the data analysis, it was concluded that each temperature increase in the hot spot will increase in the loss of life the transformer. Based on the 2017 loading data, the shrinkage of the power transformer age of the Gandul GI Unit 3 with a maximum loading on May 12, 2017 resulted in a shrinkage of 23.560% with an estimated remaining life of 34.55 years. The results for constant loading at 80% loading obtained the loss of life is 29%, at 90% loading obtained the loss of life is 103.37% and the loading of 100% obtained the loss of life is 416.6%. The magnitude of the load on transformer unit 3 of GI Gandul is 81.8% which can be used for transformers for 100% of service life..
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | transormator, thermal ageing, susut umur transormator, thermal ageing, susut umur, loss of life |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Nov 2025 04:31 |
| Last Modified: | 11 Nov 2025 04:31 |
| URI: | https://repository.itpln.ac.id/id/eprint/3719 |