Wasahua, Fadhil Aufar and Isworo, lakso (2019) EFEK PEMBEBANAN TERHADAP PENYUSUTAN UMUR TRANSFORMATOR PADA GARDU DISTRIBUSI SP120 DI PT. PLN (PERSERO) AREA KEBON JERUK. Diploma thesis, ITPLN.
SKRIPSI.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Salah satu peralatan dalam operasi sistem tenaga listrik yang sangat berperan penting adalah transformator. Transformator harus dipelihara agar dapat bertahan sesuai dengan umur yang seharusnya. Umur transformator dapat berkurang akibat pengaruh pembebanan, pembebanan yang tinggi menyebabkan kerusakan pada isolasinya. Transformator distribusi digunakan untuk membagi/menyalurkan arus atau energi listrik dengan tegangan distribusi agar jumlah energi yang hilang tidak terlalu banyak. Pada skripsi ini menggunakan metode kuantitatif dimana data yang dikumpulkan berupa angka, pengolahan data menggunakan rumus-rumus dan hasilnya juga berupa angka. Berdasarkan SPLN D3.002-1.2007 dan standart IEEE C57.91-2011 umur transformator ditetapkan selama 20,55 tahun (7500,75 hari). Transformator distribusi yang digunakan adalah transformator distribusi dengan pendinginan ONAN dan jenis beban pelanggan rumah tangga. Dari hasil perhitungan pada transformator distribusi, nilai susut umur untuk transformator pada gardu SP120 adalah 2,6132 jam per hari atau 0.0015 % per hari. Sehingga jika transformator tersebut pembebanan tertinggi hanya terjadi pada tanggal 15 Oktober 2018 saja,maka umur transformator tersebut dapat mencapai tahun 2025 dan masih tersisa 7 tahun.
One of the equipment in operation this traction system that is an important role is transformer. transformer to be maintained in order to survive in accordance with age. I'm transformer to decrease due to the influence of loading, the loading caused aging in isolation. Transformer distribution used to membagi/menyalurkan the flow of energy or electricity with the voltage distribution to the number of missing energy is not too much. In the thesis is using the method of quantitative where the data collected in the form of numbers, data processing using formulas and the result is also in the form of numbers. Based on D3.002-1.2007 and standart IEEE C57.91-2011 the age of transformer is set for 20, 55 years (7,500, 75 days). transformer in its use is transformer distribution with cooling ONAN and the type of the burden of domestic subscribers. From the results of calculations on the transformer of distribution, the shrinkage was to transformer to dump SP120 is 2,6132 hours per day or 0.0015 % per day. So that if the transformer is the highest loading only occurs on October 15,2018, then the life of the transformer can reach 2025 and there are still 7 years left.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | transformator distribusi, susut umur, beban. ransformer of distribution, shrinkage, the loading. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Nov 2025 06:48 |
| Last Modified: | 11 Nov 2025 06:48 |
| URI: | https://repository.itpln.ac.id/id/eprint/3726 |