TUDI SUSUT UMUR TRANSFORMATOR DISTRIBUSI AKIBAT PENGARUH TEMPERATUR PADA PT PLN (PERSERO) AREA SURAKARTA UPJ SUMBERLAWANG

Larasati, Ririn Budi and Hajar, Ibnu (2018) TUDI SUSUT UMUR TRANSFORMATOR DISTRIBUSI AKIBAT PENGARUH TEMPERATUR PADA PT PLN (PERSERO) AREA SURAKARTA UPJ SUMBERLAWANG. Diploma thesis, ITPLN.

[thumbnail of RIRIN BUDI LARASATI.pdf] Text
RIRIN BUDI LARASATI.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Salah satu peralatan dalam operasi sistem tenaga listrik yang sangat berperan penting adalah transformator. Transformator harus dipelihara agar dapat bertahan sesuai dengan umur yang seharusnya. Umur transformator dapat berkurang akibat pengaruh temperatur, temperatur yang tinggi menyebabkan penuaan pada isolasinya. Transformator distribusi merupakan suatu peralatan listrik yang mempunyai peranan langsung untuk pendistribusian listrik ke pelanggan. Transformator distribusi digunakan untuk membagi/menyalurkan arus atau energi listrik dengan tegangan distribusi agar jumlah energi yang hilang tidak terlalu banyak. Pada skripsi ini menggunakan metode kuantitatif dimana data yang dikumpulkan berupa angka, pengolahan data menggunakan rumus-rumus dan hasilnya juga berupa angka. Berdasarkan SPLN 50/97 dan standart IEEE C57.91-2011, suhu sekitar berkisar 30 ºC dengan suhu titik panas 98 ºC – 110 ºC umur transformator ditetapkan selama 20,55 tahun (7500,75 hari). Transformator distribusi yang digunakan adalah transformator distribusi dengan pendinginan ONAN dan jenis beban pelanggan rumah tangga. Dari hasil perhitungan pada dua buah transformator distribusi, nilai susut umur untuk transformator B1-144/285Q adalah 7,436 jam per hari atau 0,004130 % per hari dan untuk transformator B1-285/10 adalah 8,116 jam per hari atau 0,004508 % perhari. Apabila susut umur transformator terjadi setiap hari sesuai dengan perhitungan, maka umur transformator B1-144/285Q hanya bertahan 14 tahun dan transformator B1-285/10 hanya bertahan 13 tahun.

One of the equipment in operation of electric power system that’s very important is the transformer. The transformer must be maintained in order to survive according to its age. The life of transformer can be reduced due to the influence of temperature, high temperatures cause aging in the insulation.Distribution transformer is an electrical equipment that has a direct role for the distribution of electricity to customers. Distribution transformer used for divide/distribute the current or electrical energy with voltage distribution so the amount of the lost of energy is not too much. In this skripsi uses a quantitative method where data collected in the form of numbers, processing data using formulas and the results are also numbers. Based on SPLN 50/97 and IEEE standard C57.91- 2011, the temperature is about 30ºC with hot spot temperature 98 ºC – 110 ºC age of transformer has set for 20,55 years (7500,75 days). Distribution transformer used is distribution transformer with ONAN cooling and the type of load is household customers. From the calculation on two distribution transformer, value loss of life transformer B1-144/285Q is 7,436 hours a day or 0,004130 % in one day and the transformer B1-285/10 is 8,116 hours a day or 0,004508 % in one day. If loss of life transformer occurs daily according the calculation, then the transformer’s life B1-144/285Q only lasted 14 years and transformer B1-285/10 only lasted 13 years.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: transformator distribusi, susut umur, temperatur. distribution transformer, loss of life, temperature.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 11 Nov 2025 06:59
Last Modified: 11 Nov 2025 06:59
URI: https://repository.itpln.ac.id/id/eprint/3730