Abstract
Transformator atau Trafo adalah suatu alat listrik yang dapat mengubah taraf suatu tegangan AC ke taraf yang lain. Maksud dari pengubahan taraf tersebut diantaranya seperti menurunkan Tegangan AC dari 11 kV ke 380 V ataupun menaikan Tegangan dari 11 kV ke 20 kV. Karena fungsi ini, maka transformator harus dijaga agar tidak terjadi gangguan internal dan eksternal yang dapat memicu kerusakan pada komponen didalam transformator yang dapat mengganggu proses penyaluran tenaga listrik. Untuk mengurangi akibat dari gangguan pada transformator tersebut dan menjaga kelangsungan tenaga listrik yang biasa digunakan, diperlukan sistem proteksi yang sesuai dengan kebutuhan. Sistem proteksi yang dipakai adalah rele differensial. Rele differensial digunakan sebagai proteksi utama pada transformator dan tidak dapat dijadikan proteki cadangan. Rele ini bekerja dengan membandingkan arus yang masuk dan arus keluar. Rele akan mendeteksi adanya gangguan dan menginstruksikan pemutus tenaga (PMT) untuk membuka (trip).
Transformator or Trafo is an electric device which can change an AC voltage level to another level. The meaning of changing level such as decreasing AC voltage from 11 kV to 380 kV or increasing voltage from 11 kV to 20 kV. Because of the external function that can trigger damage of component inside the transformer that can disrupt process. To decrease the effect from breakdown of that transformator and maintain continuity electric power that commonly used, required a protection system as needed. The protection system used is relay differential. Differential relay are used as main protection and cannot be used as a backup protection. This relay works by comparing the current of incoming and outgoing flows. Relay wil detect fault and instructs circuit braker (CB) to open (trip).
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Proteksi, rele diffrensial Transformer, Protection, relay diffrential |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Nov 2025 07:06 |
| Last Modified: | 11 Nov 2025 07:06 |
| URI: | https://repository.itpln.ac.id/id/eprint/3732 |