KAJIAN PERHITUNGAN KAPASITAS PEMUTUSAN PMT PADA TEGANGAN SISI 20 KV DI GARDU INDUK BINTARO

Alfriyandi, Denil and suwarno, suwarno (2018) KAJIAN PERHITUNGAN KAPASITAS PEMUTUSAN PMT PADA TEGANGAN SISI 20 KV DI GARDU INDUK BINTARO. Diploma thesis, ITPLN.

[thumbnail of Skripsi (Denil Alfriyandi).pdf] Text
Skripsi (Denil Alfriyandi).pdf
Restricted to Registered users only

Download (2MB)

Abstract

Dalam sistem tenaga listrik khususnya pada tegangan sisi 20 kV, merupakan jaringan yang menyalurkan listrik dari gardu induk ke konsumen. Namun saat operasi kerjanya, sering terjadi gangguan seperti hubung singkat, sambaran petir, dan sebagainya. Besarnya arus gangguan hubung singkat yang mungkin terjadi dalam sistem tenaga listrik perlu diketahui untuk perencanaan peralatan proteksi. Salah satu alat proteksi jaringan listrik adalah pemutus tenaga (circuit breaker) yang berfungsi untuk membuka dan menutup rangkaian listrik pada semua kondisi, termasuk gangguan arus hubung singkat. Penentuan kapasitas pemutus tenaga pada tegangan sisi 20 kV dapat ditentukan dengan menghitung nilai arus hubung singkat terbesarnya. Dari hasil perhitungan besar arus hubung singkat untuk gangguan di busbar 20 kV adalah 18,57655 kA, di Gardu BT 1 adalah 9,75895 kA, di Gardu BT 2 adalah 7,07860 kA, di ujung penyulang (GH 422) 3,87834 kA dan di Gardu BT 3 (sumber mengalir melalui penyulang express) adalah 3,56340 kA)

In the electric power system, especially on the voltage side of 20 kV, is the network that distribute power from the substation to the consumer. But when operation it works, it often happens disorders such as short circuit, lightning strikes, and so on. The magnitude of the short circuit fault current which may occur in the power system need to be aware for planning protection equipment. One of the tools of protection of the electrical network is a power breaker (circuit breaker) which serves to open and close the electrical circuit in all conditions, including disorders of the short-circuit current. The determination of the capacity of the power breaker on the voltage side of 20 kV can be determined by calculating the value of the short circuit current gain. From the results of the calculation of a large short-circuit current for the interference on the busbar 20 kV is 18,57655 kA, at Substation BT 1 is 9,75895 kA, at Substation BT 2 is 7,07860 kA, at the end of feeders (GH 422) 3,87834 kA and at Substation BT 3 (the source flows through the feeders express) is 3,56340 kA.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sistem Tenaga Listrik, Pemutus Tenaga, Arus Hubung Singkat. Power System, Circuit Breaker, Short Circuit Current.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 11 Nov 2025 07:51
Last Modified: 11 Nov 2025 07:51
URI: https://repository.itpln.ac.id/id/eprint/3742