ANALISA PENGARUH HARMONISA TERHADAP TRANSFORMATOR DISTRIBUSI DI MENARA DYNAPLAST

Harefa, Ade Samuel and Pujotomo, Isworo (2018) ANALISA PENGARUH HARMONISA TERHADAP TRANSFORMATOR DISTRIBUSI DI MENARA DYNAPLAST. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI PDF.pdf] Text
SKRIPSI PDF.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Sistem distribusi tenaga listrik disetiap perusahaan atau instansi saat ini tidak dapat terhindar dari harmonisa. Karena saat ini alat-alat elektronik dengan beban non linier seperti komputer, printer, lampu hemat energi dan sebagainya sangat dibutuhkan. Beban non linier adalah pemicu timbulnya harmonisa. Harmonisa pada sistem distribusi tenaga listrik dapat mempengaruhi kinerja transformator distribusi. Seperti semakin besarnya rugi-rugi transformator, kenaikan suhu dan penurunan kapasitas (kVA) transformator. Pada skripsi ini dilakukan pengukuran harmonisa di Menara Dynaplast dan diperoleh hasil nilai THD tegangan fasa R sebesar 2,3%, fasa S sebesar 2,3%, Fasa T sebesar 2,3%. THD tegangan tidak melebihi nilai standar IEEE 519-2014 yaitu 8%. Nilai THD arus fasa R sebesar 14,2%, fasa S sebesar 18,1%, Fasa T sebesar 13,6%. THD arus melebihi nilai standar IEEE 519- 2014 yaitu 8%. Nilai batas arus harmonik ke-5 setiap fasa melebihi standar IEEE 519-2014 yaitu 7%. Rugi-rugi (losses) akibat harmonisa 16,136 kW pada fasa R sebesar 9,31 kW, fasa S sebesar 9,826 kW, fasa T sebesar 8,427 kW. Penurunan kapasitas transformator distribusi sebesar 13,924% atau 139,24 kVA. Dari 1000 kVA menjadi 860,76 kVA.

Power distribution systems in every company or agency today can not avoid harmonics. Because the current electronic devices with non-linear loads such as computers, printers, energy-saving lamps and so is needed. Non linear load is the trigger of harmonics. Harmonics on power distribution systems can affect the performance of distribution transformers. As the transformer losses increase, the temperature rise and decrease in the capacity (kVA) of the transformer. In this thesis, the measurement of harmonics in Dynaplast Tower and obtained value of THD of phase voltage R is 2,3%, phase S is 2,3%, Phase T is 2,3%. THD voltage does not exceed the IEEE 519-2014 standard value is 8%. THD value of phase current R is 14.2%, S phase is 18.1%, Phase T is 13.6%. THD current exceeds the IEEE 519-2014 standard value of 8%. The fifth harmonic current limit value of each phase exceeds the IEEE 519-2014 standard of 7%. Losses due to harmonics is 9,31 kW at the R phase, 9,826 kW at the S phase, and 8,427 kW at the T phase. Decreased distribution transformer capacity by 13.924% or 139.24 kVA. From 1000 kVA to 860,76 kVA.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: harmonisa, transformator distribusi, total harmonic distortion. harmonic, distribution transformer, total harmonic distortion
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 11 Nov 2025 08:12
Last Modified: 11 Nov 2025 08:12
URI: https://repository.itpln.ac.id/id/eprint/3745