Wijayanti, Ni Luh Ayu Eka and Prianda, Prianda (2018) ANALISIS RELE DIFERENSIAL PADA GENERATOR UNIT 1 300 MW PLTU BANTEN 2 LABUAN. Diploma thesis, ITPLN.
SKRIPSI SEMUA NI LUH AYU EKA WIJAYANTI 201411163.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Sistem proteksi memegang peranan penting dalam kelangsungan dan keamanan produksi energi listrik di PT. Indonesia Power UJP Labuan. Sistem proteksi berfungsi untuk melindungi sistem tenaga listrik, operator di sekeliling nya, dan peralatan itu sendiri dari bermacam gangguan yang mungkin terjadi. Pada pembangkit listrik peralatan yang utama adalah Generator yang berfungsi untuk mengubah energi mekanis menjadi energi listrik. PLTU Banten 2 Labuan memiliki 2 unit dengan kapasitas 600 MW. Generator yang digunakan yaitu keluaran dongfang electric machine 300 MW. Untuk menjaga keandalan dari kerja generator, maka generator dilengkapi dengan peralatan-peralatan proteksi. Peralatan proteksi generator harus mencegah kerusakan generator, karena kerusakan generator selain akan menelan biaya perbaikan yang mahal juga sangat mengganggu sistem operasi. Salah satu rele yang bekerja pada generator yaitu rele diferensial, karena sifat dari rele ini bekerja tanpa koordinasi dengan rele yang lain. Rele diferensial digunakan sebagai pengaman utama pada generator. Oleh karena itu diperlukan penyettingan rele diferensial pada generator. Setting rele diferensial yang didapat sebesar 22,5%. Didapatkan hasil perhitungan arus minimum diferensial sebesar 0,1698 A. Pada perhitungan arus hubung singkat 3 fasa yang didapatkan sebesar 11,309 kA.
Protection system plays an important role in the continuity and safety of electrical energy production in PT. Indonesia Power UJP Labuan. The protection system serves to protect the electrical power system, its surrounding operators, and the equipment itself from various interferences that may occur. In power plants the main equipment is a generator that serves to convert mechanical energy into electrical energy. PLTU Banten 2 Labuan has 2 units with a capacity of 600 MW. generator that being used is product from dongfang electric machine 300 MW. To maintain the reliability of the work of the generator, the generator is equipped with protection equipment. Generator protection equipment must prevent generator damage, because the damage generator in addition to expensive repair costs are also very disturbing the operating system. One of the relay that work on a generator is a differential relay, because the nature of these relay works uncoordinated with other relay. The differential relay is used as the primary safety of the generator. Therefore it is necessary to setup the differential relay on the generator. Differential relay settings obtained by 22,5%. Obtained the results of a differential minimum current calculation of 0.1698 A. In the calculation of the 3 phase short circuit current obtained at 11.309 kA.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Generator, proteksi, rele diferensial Generator, Protection, differential relay |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 11 Nov 2025 08:25 |
| Last Modified: | 11 Nov 2025 08:25 |
| URI: | https://repository.itpln.ac.id/id/eprint/3750 |