CHOIRIYAH, MIFTAHUL and Koerniawan, Tony (2018) KAJIAN BATAS AMAN OPERASI GENERATOR SINKRON PLTU 1X660MW PT. LESTARI BANTEN ENERGI DENGAN KURVA KAPABILITAS. Diploma thesis, ITPLN.
FULL SKRIPSI FOR CD.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Generator merupakan alat mesin listrik yang memiliki fungsi mengkonversi energi mekanik menjadi energi listrik. Dimana dalam pengoperasian generator memiliki metode dalam batas aman operasi, agar tidak mengakibatkan kerusakan pada generator. Batas aman operasi generator dapat direpresentasikan dengan sebuah kurva yang disebut dengan kurva kapabilitas. Melalui kurva kapabilitas dapat diketahui batasan kinerja sebuah generator. Batasan tersebut diantaranya batasan arus rotor, batasan arus stator, batasan daya penggerak mula dan batasan keadaan tunak. Dan dari nilai batasan yang telah diketahui melalui perhitungan, maka dapat dibentuk sebuah kurva kapabilitas generator tersebut. Setelah terbentuk kurva kapabilitas generator, maka dapat diketahui bagaimana pengaruh perubahan pembebanan terhadap generator di suatu pembangkit. Pada penelitian ini menggunakan generator dengan kapasitas daya sebesar 788 MVA dengan faktor daya 0.85 (lagging). Dan dari hasil perhitungan yang didapat batas nilai P dan Q maksimum pada generator yaitu Pout maksimum = 662.4405 MW dan Qmaksimum = 670.4898 MVAR.
Generator is a tool electric machine which has the function of converting mechanical energy into electrical energy. Where in the operation of the generator has a method within the limits of safe operation, so as not to result in damage to the generator. Safe limits of operation of the generator can be represented by a curve called capability curve. Through the capability curve can be known to limit the performance of a generator. Such limitations include limitation of the current of the rotor, limits the stator current, limitation of the power of the first mover and limitations of the steady state. And of the value of the restrictions that have been known through calculation, it can be formed of a generator capability curve. Once formed the generator capability curve, it can be seen how the influence of the change of loading the generator in a power plant. In this study, the use of generators with power capacity of 788 MVA with a power factor of 0.85 (lagging). And from the calculation results obtained boundary value of P and Q maximum on the generator that is Poutmaximum = 662.4405 MW and Qmaximum = 670.4898 MVAR.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Generator, Kurva Kapabilitas, Operasi Generator, Capability Curve, Operating |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Nov 2025 03:38 |
| Last Modified: | 12 Nov 2025 03:38 |
| URI: | https://repository.itpln.ac.id/id/eprint/3768 |