Abdullah, Firman and Sudibyo, Uno Bintang (2018) ANALISIS PENYETELAN RELAI DIFERENSIAL PADA TRAFO STEP UP 13,8/150 KV DI PLTP KAMOJANG UNIT 5. Diploma thesis, ITPLN.
SKRIPSI FIRMAN ABDULLAH.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Sistem tenaga listrik terdiri dari berbagai komponen, mulai dari komponen pembangkit, transmisi, dan distribusi yang cukup mahal, sehingga diperlukan proteksi yang baik, handal dan ekonomis untuk terhindar dari gangguan internal dan eksternal yang dapat memicu kerusakan pada komponen khususnya pada trafo tenaga di Pembangkit Listrik Tenaga Panas Bumi Kamojang Unit 5 yang dikelola oleh PT. Pertamina Geothermal Energy. Salah satu peralatan proteksi yaitu digunakan relai diferensial sebagai proteksi utama untuk memproteksi agar terhindar dari gangguan yang ada. Relai ini bekerja selektif dan cepat berdasarkan keseimbangan arus pada kedua sisi trafo tenaga yang dibantu trafo arus. Skripsi ini membahas tentang perhitungan penyetalan relai diferensial dan menghitung batas arus maksimal yang dapat mengalir pada masing-masing jaringan dengan metode yang digunakan secara kuantitatif yang dijabarkan secara deskriptif sehingga permasalahan diatas berupa angkaangka. Hasil yang diperoleh sehingga relai dapat bekerja secara baik yaitu untuk arus setting 0,33 A dan arus maksimal yang dapat mengalir pada sisi 13,8 kV yaitu 2702,7 A dan 197,66 A untuk sisi 150 kV.
The electrical power system contains of components, such as generation, transmission, and distribution which are relatively expensive and need to be protected by proper, reliable, and economical protection in purpose of avoiding internal and external faults to trigger damage on the components especially the power transformer in Kamojang Unit 5 Geothermal Generation Plant maintained by PT. Pertamina Geothermal Energy. One of the protections that is differential relay setting which is as main protection to protect and avoid the faults. The relay selectively and quickly operates depending on the balance of the current in the two sides of the power transformer assisted by current transformer. This thesis discusses about the calculation of differential relay setting and maximum current limit carried on the network using described quantitative method so that the result is numerous. The result is 0,33 A for the current setting and 2702,7 A of 13,8 kV and 197,66 A of 150 kV are the maximum current being able to flow so that the relay operates well.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | trafo daya, proteksi, relai diferensial power transformer, protection, differential |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Nov 2025 05:43 |
| Last Modified: | 12 Nov 2025 05:43 |
| URI: | https://repository.itpln.ac.id/id/eprint/3772 |