Saputro, Erwin Brahmantyo and Sudibyo, Uno Bintang (2018) KAJIAN GOVERNOR KATUP UAP TURBIN PLTU MUARA KARANG BLOK 45 MENGGUNAKAN SISTEM KONTROL TERDISTRIBUSI. Diploma thesis, ITPLN.
Erwin Brahmantyo Saputro 2014-11-135.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Kebutuhan pasokan listrik di Indonesia merupakan hal yang sangat penting bagi masyarakat. Kebutuhan tersebut harus terpenuhi dengan nilai yang berubahubah sesuai dengan penggunaan oleh pelanggan. Untuk memenuhi kebutuhan pasokan listrik tersebut maka generator akan menyuplai tenaga listrik berupa MW dan MVAR yang harus tetap dijaga stabil di atas nilai demand. Di PLTU Muara Karang sendiri memiliki masalah pada generatornya yaitu hunting MW dan MVAR saat menyuplai di nilai 160 MW. Dengan menggunakan data dari Sistem Kontrol Terdistribusi (DCS) saat terjadinya hunting serta pengujian secara online untuk mengantisipasi pembebanan rendah yang tidak terlihat, didapatkan bahwa kesalahan terjadi karena pengikisan pada piston yang menggerakkan katup governor berdasarkan karakteristik yang terbentuk karena terjadi error tertinggi sebesar 4.16%, hunting tertinggi sebesar 0.5% serta nilai hunting terendah sebesar 0.27% pada GV-RH. Yang berdampak pada ketidakmampuan generator blok 45 untuk bekerja secara sinkron sehingga menyebabkan kerusakan pada generator. Untuk menghilangkan hunting ini harus dilakukan penggantian piston pada katup governor.
The demand for electricity supply in Indonesia is very important for the community. These demands must be fulfilled with varying values according to customer usage. To meet the electricity supply needs, the generator will supply electricity in the form of MW and MVAR that must be kept stable above the demand value. At Muara Karang PLTU itself has a problem with the generator, namely MW and MVAR hunting when supplying at 160 MW. By using data from a Distributed Control System (DCS) when hunting and testing online to anticipate low unseen loading, it was found that the error occurred due to piston erosion which moved the governor valve based on the characteristics formed due to the highest error of 4.16%, hunting the highest is 0.5% and the lowest hunting value is 0.27% on GV-RH. Which has an impact on the inability of the block 45 generator to work synchronously, causing damage to the generator. To eliminate this hunting, a piston must be replaced in the governor valve.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | PLTU, MW, MVAR, Governor, DCS PLTU, MW, MVAR, Governor, DCS |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Nov 2025 12:31 |
| Last Modified: | 12 Nov 2025 12:31 |
| URI: | https://repository.itpln.ac.id/id/eprint/3794 |
