ANALISIS PARTIAL DISCHARGE DENGAN METODE PENGUJIAN GELOMBANG OSILASI PADA SALURAN KABEL TEGANGAN MENENGAH PENYULANG EONG AREA CENGKARENG

Mukti, Muhammad Irvan Fadholi and Soewono, Soetjipto (2018) ANALISIS PARTIAL DISCHARGE DENGAN METODE PENGUJIAN GELOMBANG OSILASI PADA SALURAN KABEL TEGANGAN MENENGAH PENYULANG EONG AREA CENGKARENG. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI FULL EDIT.pdf] Text
SKRIPSI FULL EDIT.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Partial discharge adalah kegagalan isolasi pada kabel yang diakibatkan rusaknya insulasi pada kabel. Hal ini merupakan indikasi terjadinya gangguan isolasi pada kabel terutama pada kabel – kabel tua dan pada kabel dengan material isolasi yang terdapat void sehingga memicu terjadi nya discharge pada isolasi.. Partial Discharge perlu dideteksi untuk menghindari terjadinya kegagalan isolasi lebih lanjut dan untuk mengetahui kondisi kabel terkini yang layak pakai. Dengan menggunakan metode OWTS (oscillating Wave Test System) yang dapat merekam aktifitas partial discharge pada kabel dengan memberikan tegangan DAC (Damped Alternating Current ) pada kabel sehingga dapat membaca gangguan yang terjadi sepanjang kabel. Penyulang Eong merupakan penyulang yang akan di uji karena sudah mengalami gangguan beberapa kali selama 2 kali pada bulan Januari. Dengan metode OWTS ini dilakukan kalibrasi dan pengukuran dengan tegangan uji dari nol sampai 2xUo maka didapatkan kondisi fasa R, S, dan T mengalami nilai PD mencapai 5000 pC pada penyulang Eong dengan jarak 20 – 30m sudah ada yang dalam kondisi buruk dan sangat buruk, sehingga memiliki estimasi waktu efektif pemakaian sekitar 3 – 12 bulan pemakaian aktif lagi.

Partial discharge is a failure of insulation on the cable caused by damage to insulation on the cable. This is an indication of the isolation disturbance on the cable, especially on the old cables and the cables with insulating material that contains voids, which triggers a discharge in insulation. Partial Discharge needs to be detected to avoid further isolation failure and to find out the condition the latest cable that is suitable for use. By using the OWTS (oscillating Wave Test System) method that can record partial discharge activity on a cable by giving a DAC (Damped Alternating Current) voltage to the cable so that it can read the disturbances that occur along the cable. Eong feeder is a feeder who will be tested because he has experienced the disorder several times for 2 times in January. With the OWTS method, calibration and measurement are carried out with a test voltage from zero to 2xUo, so the R, S, and T phase conditions have a PD value of 5000 pC on the Eong feeder with a distance of 20-30m, which is already in bad condition and very bad, so has an estimated effective usage time of about 3 - 12 months of active use again.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Partial Discharge,void, kegagalan isolasi Partial Discharge, Void, Insulation failure
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 12 Nov 2025 13:24
Last Modified: 12 Nov 2025 13:24
URI: https://repository.itpln.ac.id/id/eprint/3802

Actions (login required)

View Item
View Item