KAJIAN PENGARUH LUAS PENAMPANG PENGHANTAR DAN JARAK ANTAR FASA TERHADAP RUGI-RUGI DAYA AKIBAT KORONA PADA SUTT 150 KV (Aplikasi :Gardu Induk Kebonagung ke Gardu induk Sengkaling)

Prakoso, Danu Dwi and Susanto, djoko (2019) KAJIAN PENGARUH LUAS PENAMPANG PENGHANTAR DAN JARAK ANTAR FASA TERHADAP RUGI-RUGI DAYA AKIBAT KORONA PADA SUTT 150 KV (Aplikasi :Gardu Induk Kebonagung ke Gardu induk Sengkaling). Diploma thesis, ITPLN.

[thumbnail of SKRIPSI.pdf] Text
SKRIPSI.pdf
Restricted to Registered users only

Download (8MB)

Abstract

Korona adalah proses dimana arus muncul dari sebuah elektroda berpotensial tinggi di dalam sebuah fluida yang netral, dengan mengionisasi fluida hingga menciptakan plasma di sekitar elektroda. Dampak dari korona selain merusak peralatan, berisik, dan mengganggu gelombang radio, korona juga menimbulkan rugi-rugi daya yang besarnya berbanding lurus dengan panjang saluran transmisi. Tegangan Kritis awal terjadinya korona pada model kubikel dipengaruhi oleh beberapa hal seperti gradient tegangan ,kelembaban udara, tekanan udara dan kondisi suhu udara. hal-hal tersebut dapat memperbesar nilai rugi-rugi akibat korona. Dalam skripsi ini dengan menggunakan metode kuantitatif, dengan cara menghitung besar rugi daya korona dengan membandingkan 5 luas penampang penghantar dan 4 jarak antar fasa berbeda. Hasil dari penelitian ini didapatkan bahwa dari kelima jenis penampang, semakin kecil luas penampang kawat maka rugi-rugi daya akibat korona semakin besar, sebaliknya semakin besar luas penampang maka semakin kecil rugi-rugi daya akibat korona. Hasil dari keempat jarak antar fasa didapat bahwa, semakin kecil Jarak antar fasa maka rugi-rugi daya akibat korona semakin besar, sebaliknya semakin besar jarak antar fasa maka semakin kecil rugi-rugi daya akibat korona.

Corona is a processs of which current appears from a high potential electrode within a neutral fluid, by ionizing the fluid creating plasma around the electrode. Due to the impact of Corona, besides damaging equipment, noisy, and could interfere radio waves, Corona also generates power losses is directly proportional to the length of the transmission line. Critical voltage of corona at cubical model was influenced by many things, such as voltage gradient, humidity, air pressure, and temperature. All of that matter can increase losses due to the corona. This minithesis using quantitative mode, by calculating the corona power loss by comparing 5 conductor cross-sectional area and 4 different inter-phase distance. The results of this research obtained is that from the fourth type of crosssection, the smaller the cross-sectional area of the wire then power losses due to Corona become greater, otherwise the greater the cross-sectional area then the smaller the power losses due to the Corona. The results of the distance between phases are obtained, the smaller the distance between phases, the greater power losses from the corona, on the contrary the greater the inter-phase distance, the less power losses due to the corona.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: rugi-rugi daya, korona, luas penampang kawat, saluran transmisi power losses, Corona, the cross-sectional area of the wire, air temperature, transmission line
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 13 Nov 2025 06:55
Last Modified: 13 Nov 2025 06:55
URI: https://repository.itpln.ac.id/id/eprint/3826