KAJIAN PERENCANAAN KOORDINASI SISTEM PROTEKSI IBT 1 PADA GISTET KEMBANGAN 500 kV DENGAN MEMPERTIMBANGKAN PENGARUH PENAMBAHAN FEEDER GISTET DURI KOSAMBI 500 kV

SETIAWAN, EZRA DWI and Isworo, lakso (2018) KAJIAN PERENCANAAN KOORDINASI SISTEM PROTEKSI IBT 1 PADA GISTET KEMBANGAN 500 kV DENGAN MEMPERTIMBANGKAN PENGARUH PENAMBAHAN FEEDER GISTET DURI KOSAMBI 500 kV. Diploma thesis, ITPLN.

[thumbnail of Skripsi Ezra Dwi Setiawan 201411095.pdf] Text
Skripsi Ezra Dwi Setiawan 201411095.pdf
Restricted to Registered users only

Download (5MB)

Abstract

Transformator daya merupakan peralatan sistem tenaga listrik yang berfungsi untuk menyalurkan daya dengan mengubah besar tegangannya.oleh karena itu, transformator memiliki peranan yang sangat penting dalam sistem tenaga listrik dan harus memiliki keandalan selama beroperasi. Sehingga untuk menjaga keandalan transformator, digunakan sistem proteksi untuk melindungi transformator dari gangguan internal maupun eksternal. Sistem proteksi berfungsi untuk melindungi peralatan listrik dari gangguan yang terjadi agar peralatan tidak padam, meminimalisir daerah padam, dan waktu padam. Salah satu peralatan proteksi transformator adalah rele proteksi. Peralatan pengaman trafo ini salah satu contohnya adalah rele differensial, rele arus lebih dan rele gangguan tanah. Pada Skripsi ini, membahas mengenai perencanaan sistem proteksi yang akan dipakai untuk mengamankan IBT 1 Kembangan 500/150 kV dengan pengaman yaitu rele diferensial, rele hubung tanah, rele arus lebih. Untuk penyetelan rele diferensial pada sisi 500 dan 150 kV sudah sesuai dengan SPLN yaitu minimum setting 30%. Di sisi 150 kV trafo, rele arus lebih memiliki nilai arus pick-up dan tms sebesar 0,846 A dan 0,075. Sedangkan untuk rele hubung tanah sebesar 0,770 A dan 0,158. Di sisi 500 kV trafo, rele arus lebih memiliki nilai arus pick-up dan tms sebesar 0,635 A dan 0,175. Sedangkan untuk rele hubung tanah sebesar 0,116 A dan 0,29.

Power transformer is an electrical device which function is to distribute electrical power and changes the value of its voltages. Owing to this, transformer have an important role in the power system and needs to have reliability when it operates. This is attainable by installing protection tools to avoid the internal and external interferences. Protection system protects electrical equipments from the disturbances so that the equipments will not be damaged, also to minimize the blackout times and areas. One of transformer protection apparatus is protection relay. These transformer protection tools are differential relay, over current relay, and ground fault relay. In this thesis talks about a design of protection system that will be used to protect IBT-1 500 Kv GISTET Kembangan with differential relay protection, over current relay and ground fault relay. On both side (HV and LV) of transformer, the setting of differential relay are already suitable with SPLN, which the minimum setting value is 30%. On 150 kV side of transformer, over-current relay has pick-up current and tms value are 0,846 A and 0,075. While for ground fault relay are 0,770 A and 0,158. On 500 kV side of transformer, over-current relay has pick-up current and tms value are 0,635 A and 0,175. And for ground fault relay are 0,116 A and 0,29.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator, Gangguan, Sistem Proteksi. Transformer, Faults, Protection System.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 13 Nov 2025 08:13
Last Modified: 13 Nov 2025 08:13
URI: https://repository.itpln.ac.id/id/eprint/3835