Koordinasi isolasi dinyatakan sebagai metode untuk menghindari kerusakan terhadap peralatan listrik karena tegangan lebih. Tegangan lebih disebabkan oleh faktor internal seperti surja hubung dan juga faktor eksternal seperti surja petir. Tegangan lebih yang besarnya melebihi nilai tingkat isolasi dasar atau Basic Insulation Level (BIL) suatu peralatan akan menyebabkan kerusakan pada peralatan tersebut. Peralatan utama yang harus dilindungi di gardu induk dalam masalah koordinasi isolasi adalah transformator. Arester adalah alat pelindung utama dalam koordinasi isolasi di gardu induk. Dalam penelitian ini akan dilakukan studi dalam masalah koordinasi isolasi pada GISTET 500 kV di Kembangan. Tujuan utama dari penelitian ini adalah untuk mengetahui tingkat perlindungan arester terhadap transformator dengan menggunakan kurva voltwaktu. Kurva volt-waktu menggambarkan ketahanan isolasi transformator dan tingkat perlindungan arester terhadap tegangan lebih. Pada penelitian ini, diketahui bahwa tegangan lebih yang masuk ke transformator melebihi nilai tingkat isolasi dasar transformator, yaitu untuk surja petir bernilai 2776 kV dan untuk surja hubung bernilai 1633 kV. Sementara ketahanan isolasi transformator untuk surja petir bernilai 1550 kV dan untuk surja hubung bernilai 1300 kV. Dilihat dari tingkat perlindungan arester pada kurva volt-waktu, arester yang terpasang di GISTET Kembangan sudah cukup untuk melindungi peralatan dari tegangan lebih surja petir maupun surja hubung.

Insulation coordination is expressed as the method to avoid the damage of electrical equipment that is caused by over voltages. Over voltages are caused by internal factor such as switching surge and external factor such as lightning surge. Over voltages which its value higher than Basic Insulation Level (BIL) of equipment will caused damage for those equipment. The main equipment that must be protected in insulation coordination problem for substation is transformer. Arrester is the main protection device in insulation coordination for substation. The problem of Insulation coordination at Gas Insulated Switchgear (GIS) for Extra High Voltage 500 kV in Kembangan will be studied in this research. The main purpose from this research is to know protection level of arrester toward the transformer with volt-time curve. Volt-time curve describes insulation endurance of transformer and arrester protection level toward over voltages. In this research, is known that the value of over voltages which go into the transformer is higher than the insulation level of transformer, voltage value for lightning surge is 2776 kV and voltage value for switching surge is 1633 kV. However, the endurance of transformer insulation for lightning surge is 1550 kV and for switching surge is 1300 kV. Seen from arrester characteristic at volt-time curve, arrester that is applied at GIS Kembangan has been enough to protect the transformer from over voltages those come from lightning surge or switching surge.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: koordinasi isolasi, arester, tegangan lebih, transformator, surja. insulation coordination, arrester, over voltage, transformer, surge.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 16 Nov 2025 10:25
Last Modified: 16 Nov 2025 10:25
URI: https://repository.itpln.ac.id/id/eprint/3896

Actions (login required)

View Item
View Item