EVALUASI REKONFIGURASI JARINGAN DI PENYULANG KURIKULUM 20 kV MENGGUNAKAN SOFTWARE ETAP 12.6.0

Jamil, Maulana Chasan and Susanto, djoko (2018) EVALUASI REKONFIGURASI JARINGAN DI PENYULANG KURIKULUM 20 kV MENGGUNAKAN SOFTWARE ETAP 12.6.0. Diploma thesis, ITPLN.

[thumbnail of Full_Skrip_MCJ.pdf] Text
Full_Skrip_MCJ.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Pada sistem distribusi tenaga listrik, permasalahan yang umum terjadi adalah perbedaan nilai tegangan listrik yang dikirim dari suatu gardu distribusi dengan nilai tegangan listrik yang diterima pelanggan atau konsumen di sekitar gardu distribusi tersebut terletak. Fenomena perbedaan nilai tegangan listrik ini disebut dengan jatuh tegangan. Fenomena ini dapat juga terjadi pada tegangan menengah suatu penyulang. Penyebab umumnya jatuh tegangan terjadi dikarenakan pertumbuhan beban dari gardu distribusi lain yang terletak pada suatu penyulang yang sama dan dapat juga disebabkan karena penggelaran Saluran Kabel Tanah Tegangan Menengah (SKTM) dengan panjang saluran yang berlebih sehingga menyebabkan meningkatnya nilai impedansi saluran yang secara langsung juga meningkatkan nilai jatuh tegangan pada suatu penyulang. Untuk memperbaiki nilai jatuh tegangan terdapat beberapa metode yang dapat digunakan salah satunya dengan rekonfigurasi jaringan. Selain penerapan metode yang tepat, diperlukan juga kemampuan untuk mendesain jaringan yang optimal dengan pendekatan – pendekatan yang umumnya digunakan oleh seorang perancang jaringan. Dalam skripsi ini akan dibahas mengenai perbaikan jatuh tegangan yang terjadi pada sisi distribusi primer dengan menggunakan software ETAP versi 12.6.0 untuk menyimulasikan jaringan berdasarkan diagram satu garis sehingga mendapatkan nilai arus beban dan prosen jatuh tegangan pada penyulang yang diterapkan rekonfigurasi.

In power distribution system, problem that generally occurs is the different of voltage value which sent from a distribution substation and voltage value that received by consumer in area where that distribution substation located. This Phenomenon of different voltage value usually called as voltage drop. It can be occured on medium voltage of feeder too. Generally it caused by load growth from the other distribution substation which located in same feeder also it can be caused by Medium Voltage Underground Cable which spread excessively that can result of increasing value of cable impedance that directly increasing the value of voltage drop in a feeder too. To fixs it, there are some methods which can be applied, one of these methods is network re-configuration. Beside applied the right method, ability to design an optimal network with several approaches which generally used by a network planner needed too. In this minithesis will be disscussed about fixing voltage drop that occurs in primary distribution side using software ETAP version 12.6.0 to simulate the network based on real one line diagram on feeder that applied network reconfigu

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Rekonfigurasi, Jatuh Tegangan, Pendekatan Reconfiguration, Voltage Drop, Approach
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 19 Nov 2025 15:48
Last Modified: 19 Nov 2025 15:48
URI: https://repository.itpln.ac.id/id/eprint/3953

Actions (login required)

View Item
View Item