ZALUKHU, LILIS MARYANTI and Willy, Purnomo (2018) ANALISIS PENGARUH DISTORSI HARMONISA TOTAL PADA PELANGGAN PT. PALAPA PRIMA. Diploma thesis, ITPLN.
ANALISIS PENGARUH DISTORSI HARMONISA TOTAL PADA PELANGGAN PT PALAPA PRIMA.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Dengan meningkatnya pertumbuhan ekonomi maka kebutuhan atau daya beli masyarakat terhadap beban listrik semakin meningkat pula, hal ini dilihat semakin meningkatnya pemakaian peralatan elektronik yang semakin meningkat. Disisi lain dengan meningkatnya pemakaian peralatan elektronik tersebut, ada dampak atau pengaruh yang tidak baik pada sistem ketenagalistrikan. Hal tersebut disebabkan oleh beban tidak seimbang atau non linear yang mengakibatkan munculnya harmonisa pada sistem ketenagalistrikan. Dengan adanya harmonisa maka kualitas daya yang disalurkan menjadi menurun dan menyebabkan kerusakan akibat panas yang berlebihan pada peralatan listrik. Adapun nilai THD (Total Harmonic Distortion) yang ada pada pelanggan dapat dibaca melalui AMR (Automatic Meter Reading) dengan tipe MK6 yang dapat dicatat secara realtime. Hasil pembacaan menunjukkan bahwa nilai THD tegangan dan THD arus yang dimulai jam 14:00-17:00 WIB pada pelanggan PT Palapa Prima telah melebihi standar IEEE 519-1992, dimana standar harmonisa tegangan sebesar 5% dan standar harmonisa arus sebesar 12 %. Harmonisa juga mengakibatkan derating transformator distribusi sebesar 8.03 %.
By the increasing of economic growth, the need or purchase power of the people towards the electricity burden is increasing as well. This is seen by the increasing use of eletronic equipments. On the other hand, by the increasing use of electronic equipments, there is a bad impact of infulence on the electricity system. This is caused by unbalanced or non linear loads that make the emergence of harmonics on the electricity system. By having the harmonics, the quality of the distributed power decreases and causes damage doe to excessive heat in eletrical equipment. The value of THD (Total Harmonic Distortion) which is on customers can be read through AMR (Automatic Meter Reading) with MK6 type which can be recorded in realtime. The reading result shows that the voltage THD and current THD values start at 14:00 to 17:00 WIB on PT Palapa Prima customers have exceeded the IEEE 519-1992 standard, where the standard harmonic voltage is 5% and the current harmonic standard is 12%. Harmonic also causes derating a distribution transformer of 8.03%.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Harmonisa, Beban Non Linear Harmonics, Non linear load |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 19 Nov 2025 15:58 |
| Last Modified: | 19 Nov 2025 15:58 |