ANALISA PERHITUNGAN KOORDINASI SETTING RELAI ARUS LEBIH DAN RELAI GANGGUAN TANAH DI SISTEM PROTEKSI PENYULANG 20 KV GARDU INDUK PADANG LUAR

Saren, Sutan Gunawan and Susanto, djoko (2019) ANALISA PERHITUNGAN KOORDINASI SETTING RELAI ARUS LEBIH DAN RELAI GANGGUAN TANAH DI SISTEM PROTEKSI PENYULANG 20 KV GARDU INDUK PADANG LUAR. Diploma thesis, ITPLN.

[thumbnail of Skripsi Sutan [201411028].pdf] Text
Skripsi Sutan [201411028].pdf
Restricted to Registered users only

Download (6MB)

Abstract

Jaringan Distribusi merupakan salah satu sistem tenaga listrik yang tidak dapat terhindar dari gangguan, khususnya gangguan hubung singkat, baik hubung singkat tiga fasa, fasa dengan fasa atau hubung singkat antara fasa dengan tanah. Untuk melokalisasi gangguan tersebut diperlukan sistem proteksi yang memenuhi persyaratan sensitifitas, keandalan, selektifitas dan kecepatan. Peralatan proteksi yang sering digunakan pada sistem distribusi adalah over current relay (OCR) dan ground fault relay (GFR), yaitu relai yang berfungsi memberi perintah PMT untuk membuka, sehingga saluran yang terganggu dipisahkan dari jaringan. Dalam penelitian ini membahas tentang sistem pengamanan dari gangguan hubung singkat antar fasa dengan fasa menggunakan OCR dan gangguan hubung singkat fasa dengan tanah mengunakan GFR sebagai pengaman, dan perhitungan koordinasi setting relai OCR dan GFR. Lokasi penelitian adalah pada penyulang F6 Belakang Balok di gardu induk Padang Luar. Dimana perhitungan yang dilakukan secara manual dan dibantu program Microsoft Exel. Dari hasil perhitungan arus gangguan hubung singkat yang didapat, kemudian dihitung settingan relai OCR dan GFR yang terpasang pada sisi incoming dan outgoing. Setelah itu hasil perhitungan setting relai dibandingkan dengan hasil setting relai tang terpasang pada jaringan distribusi 20 kV Gardu Induk Padang Luar di penyulang F6 Belakang Balok.

Distribution Network is one of the electric power systems that cannot avoid interference, especially short circuit disturbances, both three phase short circuit, phase with phase or short circuit between phase and ground. To localize the interference, a protection system is needed which meets the requirements of sensitivity, reliability, selectivity and speed. Protection equipment that is often used in distribution systems is over current relay (OCR) and ground fault relay (GFR), which is a relay that functions to give PMT commands to open, so that the disturbed channels are separated from the network. In this study discussed the security system of short circuit inter phase with phase using OCR and phase-toground short circuit using GFR as a safety, and calculating the coordination of OCR and GFR relay settings. The location of the study was the feeder F6 Belakang Balok at the Padang Luar substation. Where calculations are done manually and assisted by the Microsoft Exel program. From the calculation of the short circuit fault current obtained, then the OCR and GFR relay settings are calculated which are installed on the incoming and outgoing sides. After that, the calculation of the relay settings is compared with the results of the relay settings installed on the distribution network of 20 kV Padang Luar Substation in F6 Belakang Balok.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Arus Hubung Singkat, Relai Arus Lebih, Relai Gangguan Tanah Short Circuit Current, Over Current Relay, Ground Fault Relay
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 20 Nov 2025 13:49
Last Modified: 20 Nov 2025 13:49
URI: https://repository.itpln.ac.id/id/eprint/3983