KAJIAN TEGANGAN SENTUH DAN TEGANGAN LANGKAH PADAPEMBUMIAN GARDU INDUK KEMAYORAN

WICAKSONO, DWI PRATIKTO and suwarno, suwarno (2018) KAJIAN TEGANGAN SENTUH DAN TEGANGAN LANGKAH PADAPEMBUMIAN GARDU INDUK KEMAYORAN. Diploma thesis, ITPLN.

[thumbnail of Skripsi Dwi Pratikto Wicaksono.pdf] Text
Skripsi Dwi Pratikto Wicaksono.pdf
Restricted to Registered users only

Download (5MB)

Abstract

Sistem tenaga listrik selalu bertumbuh begitu juga dengan pembangkitan dan jaringan pada sistem tenaga listrik yang mana dapat mempengaruhi besarnya gangguan arus hubung singkat. Besarnya arus hubung singkat yang menuju gardu induk kemungkinan mempengaruhi semakin besarnya tegangan sentuh dan tegangan langkah pada pembumian gardu induk, sehingga perlu diadakan pengkajian untuk sistem pembumian gardu induk. Sistem pembumian pada gardu induk merupakan sesuatu yang amat penting karena bertujuan untuk menghindari bahaya-bahaya terhadap manusia dan peralatan yang berada didalam atau didaerah gardu induk tersebut. Skripsi ini bertujuan untuk mengetahui sistem pembumian pada Gardu Induk Kemayoran baik dan layak atau tidak dengan menghitung tegangan sentuh dan tegangan langkah maksimumnya, dimana hasilnya mengacu pada standar IEEE Standart 80-2000. Analisa yang diperoleh mandapatkan kesimpulan tegangan sentuh dan tegangan langkah maksimal tidak melebihi dari tegangan sentuh dan tegangan langkah yang diizinkan. Dimana tegangan sentuh maksimalnya bernilai 237,55 Volt dan tegangan langkah maksimum bernilai 138,94 Volt, sedangkan tegangan sentuh dan tegangan langkah yang diizinkan bernilai 258,68 Volt dan 686,72 Volt.

Electric power systems are always growing so also with the generation and the network of the power system which can affect the magnitude of interference short circuit current. The magnitude of the short-circuit current toward the substation is likely to affect the magnitude of the touch voltage and step voltage on the grounding substations, so there should be a review for grounding systems of substations. The grounding system at the substations is something that is very important because it aims to avoid the dangers to humans and equipment located in or in the substation. This thesis aims to determine the grounding systems in Kemayoran Substations better and worth or not by calculating the touch voltage and step voltage the maximum, where the results refer to the IEEE Standard 80-2000. The analysis of obtained get the conclusion of the touch voltage and step voltage the maximum does not exceed the touch voltage and step voltage are allowed. Where is the touch voltage maximum value 237,55 Volts and the voltage step the maximum value 138,94 Volts, while the touch voltage and step voltage allowed value 258,68 Volt and 686,72 Volts.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Pembumian, Gardu Induk, Tegangan Sentuh, Tegangan Langkah Pembumian, Gardu Induk, Tegangan Sentuh, Tegangan Langkah
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 20 Nov 2025 15:00
Last Modified: 20 Nov 2025 15:00
URI: https://repository.itpln.ac.id/id/eprint/3992

Actions (login required)

View Item
View Item