Handrian, Ridwan and Soewono, Soetjipto (2018) ANALISIS PENGARUH PEMASANGAN KAWAT TANAH PADA SALURAN UDARA TEGANGAN MENENGAH 20 KV PENYULANG PROTOKOL PT. PLN (PERSERO) AREA DEPOK DARI GANGGUAN PETIR. Diploma thesis, ITPLN.
SKRIPSI RIDWAN HANDRIAN.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Saluran udara memiliki potensi gangguan akibat sambaran petir. Kawat tanah adalah pelindung SUTM terhadap gangguan petir akibat sambaran langsung dan sambaran tidak langsung. Selain kawat tanah, arester juga berperan melindung peralatan (trafo dan kabel) pada SUTM. Untuk mengetahui pengaruh pemasangan kawat tanah pada SUTM dilakukan penelitian gangguan petir pada SUTM sebelum dan setelah dipasang kawat tanah. Penelitian ini juga akan melihat pengaruh arester yang dipasang pada SUTM. Yang mana arester digunakan untuk melindungi peralatan SUTM, namun juga memiliki efek perlindungan pada SUTM karena adanya jarak lindung arester. Penelitian ini dilakukan pada SUTM penyulang Protokol PT. PLN (Persero) Area Depok. Tujuan penelitian ini adalah untuk mengetahui pengaruh pemasangan kawat tanah sebagai pelindung SUTM dan pemakaian arester sebagai pelindung peralatan. Dari hasil perhitungan total jarak lindung arester pada SUTM sebesar 2,724 km. Jumlah gangguan petir pada SUTM sebelum dipasang kawat tanah adalah 3,477 gangguan/tahun dan setelah dipasang kawat tanah sebesar 1,932 gangguan/tahun. Sehingga pengurangan jumlah gangguan petir setelah dipasang kawat tanah adalah 44,434 %.
Overhead line has potential disturbances due to lightning strikes. A grounding wire is a medium voltage overhead line protector against due to direct strike and indirect strike. In addition to the grounding wire, the arrester also behaves as a protective device (transformer and wire) of medium voltage overhead line. In purpose to understand the effect of grounding wire installation at the medium voltage overhead line then a research of lightning disturbance at the medium voltage overhead line is conducted before and after the installation of grounding wire. This study will also look at the effect of arresters mounted on the medium voltage overhead line. The arrester is used to protect the medium voltage overhead line equipment, but also has a protective effect on the medium voltage overhead line due to the distance arrester. This research was conducted on the medium voltage overhead line Protokol feeder of PT. PLN (Persero) Depok Area. The purpose of this research is to know the effect of the installation of grounding wire as medium voltage overhead line protector and the use of arrester as protective equipment. From the calculation result of total arrest range of arresters at the medium voltage overhead line is 2,724 km. The number of lightning disturbances at the medium voltage overhead line before the installation of grounding wire installed is 3,477 disruptions/year and after installation of grounding wire of 1,932 disruptions/year. So, the reduction number of lightning disturbances after installation of the grounding wire is 44,434 %.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Kawat Tanah, Arester, SUTM, Gangguan petir Grounding Wire, Arrester, Medium Voltage Overhead Line, Lightning disturbance |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 20 Nov 2025 15:26 |
| Last Modified: | 20 Nov 2025 15:26 |
| URI: | https://repository.itpln.ac.id/id/eprint/3996 |