Rahmananda, Dimas Arsy and Susanto, djoko (2016) ANALISA JATUH TEGANGAN DAN PERBAIKAN FAKTOR DAYA PADA JARINGAN TEGANGAN MENENGAH 20 KV PENYULANG HOPAX DI GARDU INDUK NGORO. Diploma thesis, ITPLN.
Skripsi (Dimas Arsy Rahmananda - 2012-11-092).pdf
Restricted to Registered users only
Download (1MB)
Abstract
Perkembangan industri dan rumah tangga saat ini tentu akan mempengaruhi penggunaan beban listrik. Besarnya permintaan beban serta jauhnya letak beban dari pusat pembangkit mengakibatkan masalah dalam penyaluran daya listrik terutama masalah jatuh tegangan. Bagi pelanggan industri yang mayoritas bebannya bersifat induktif, tentu berpotensi mengalami jatuh tegangan yang lebih besar karena jika faktor daya rendah maka arus beban listrik yang disuplai dari PLN semakin besar, sehingga menyebabkan jatuh tegangan pada saluran. Untuk mengurangi jatuh tegangan pada saluran penyulang Hopax diperlukan metode analisa jatuh tegangan serta perbaikan faktor daya pada salah satu beban. Besarnya jatuh tegangan pada ujung penyulang Hopax untuk hari kerja sebesar 2,514% dan hari libur sebesar 0,433%. Sesuai dengan SPLN No.72 tahun 1987, Jatuh tegangan tersebut masih dalam batas toleransi PT.PLN (Persero). Setelah melakukan perbaikan faktor daya pada salah satu beban dengan kapasitor shunt, jatuh tegangan pada ujung saluran menjadi 2,453% pada hari kerja dan 0,375% pada hari libur. Pemasangan kapasitor merupakan salah satu cara efektif untuk mengurangi jatuh tegangan pada jaringan tegangan menengah yang berada di kawasan industri.
The development of industrial and household current will certainly affect the use of electrical load. The magnitude of the load demand and away lies the burden of plants lead to problems in the distribution of electrical power mainly voltage drop problem. For industrial customers, the majority of the load is inductive, certainly have the potential to experience a voltage drop greater because if the low power factor, the current electrical load supplied from PLN getting bigger, causing the voltage drop across the channel. To reduce the voltage drop across the feeder channel Hopax required voltage drop analysis methods as well as power factor improvement on one load. The magnitude of the voltage drop at the end of the feeder Hopax to 2.514% of working days and holidays amounting to 0.433%. In accordance with SPLN 72 1987, the voltage drop is still within tolerable limits PT PLN (Persero). After making the power factor improvement on one load to the shunt capacitor, the voltage drop at the end of the line becomes 2.453% on weekdays and 0,375% on holidays. Installation of capacitor is one effective way to reduce the voltage drop across the medium voltage networks is in an industrial area.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Jaringan tegangan menengah, Jatuh tegangan, Perbaikan faktor daya. Medium voltage networks, Voltage drop, Power factor improvement. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 21 Nov 2025 05:00 |
| Last Modified: | 21 Nov 2025 05:00 |