STUDI KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PLTGU PANARAN

Putra, Pristian Dwi and Willy, Purnomo (2016) STUDI KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PLTGU PANARAN. Diploma thesis, ITPLN.

[thumbnail of 1. Cover Skripsi.pdf] Text
1. Cover Skripsi.pdf

Download (173kB)
[thumbnail of 2. Bagian Awal.pdf] Text
2. Bagian Awal.pdf

Download (334kB)
[thumbnail of BAB I.pdf] Text
BAB I.pdf

Download (198kB)
[thumbnail of BAB II.pdf] Text
BAB II.pdf

Download (1MB)
[thumbnail of BAB III.pdf] Text
BAB III.pdf
Restricted to Registered users only

Download (385kB)
[thumbnail of BAB IV.pdf] Text
BAB IV.pdf
Restricted to Registered users only

Download (2MB)
[thumbnail of BAB V.pdf] Text
BAB V.pdf
Restricted to Registered users only

Download (89kB)
[thumbnail of Penutup.pdf] Text
Penutup.pdf

Download (122kB)

Abstract

Dengan penambahan unit baru pada PLTGU Panaran maka evaluasi terhadap sistem proteksi mutlak diperlukan untuk menjamin keandalan dari sistem pembangkit. Salah satu cara adalah memperhatikan koordinasi rele proteksi dengan memfungsikan rele sebagai proteksi utama dan proteksi cadangan. Rele proteksi yang dapat dikoordinasikan dengan yang lain adalah rele arus lebih (Overcurrent Relay) dan rele gangguan tanah (Ground Fault Relay). Hal ini dilakukan dengan menganalisa ulang setelan rele proteksi arus lebih dan rele gangguan tanah serta menggambarkan kurva karakteristik koordinasinya. Untuk melakukan perhitungan setelan rele perlu memperhatikan nilai arus hubung singkat, nilai beban, dan data peralatan yang terkait. Kemudian perhitungan setelan rele dibandingkan dengan setelan rele yang ada di lapangan. Dari analisa koordinasi secara keseluruhan sudah disetel dengan baik. Namun masih terdapat beberapa setelan yang kurang tepat yaitu pada rele 50 transformator step up PLTG dan rele 51 generator turbin gas yang terlalu rendah sehingga setelan arus disarankan dinaikkan sesuai perhitungan. Sedangkan pada koordinasi rele gangguan tanah setelan waktu rele transformator auxiliary, motor BFW, dan motor CWP dapat dibuat lebih rendah agar kinerja rele lebih cepat dalam mendeteksi arus gangguan.

With the addition of new unit on Panaran Combined Cycle Power Plant, the evaluation of the proctection system is absolutely necessary to ensure the reliability system of powet plant. One way is pay attention to protection coordination with enabled relay as main and backup protection. Protection relay that can be coodinated is overcurrent relay (OCR) and ground fault relay (GFR). That is by analyzing the protection setting of overcurrent relay and ground fault relay then describing the protective relay time characteristic curve. To perform the calculation protective relay settings need to pay attention to the value of short circuit current, load list, and related equipments. And then calculation for relay setting are compared to the existing relay setting. Overall from the analysis coordination, the existing relay setting has been tuned properly. However there are some settings that are less precise. That is 50 device of step up transformer and 51 device of gas turbine generator. The value of current setting are too low. So that current settings are advised raised according to the calculations. While the coordination of ground fault relay, time setting of auxiliary transformers, BFW motor, and CWP motor can be made lower for faster relay performance in detecting the fault current.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Rele Arus Lebih, Rele Gangguan Tanah, Koordinasi rele Overcurrent Relay, Ground Fault Relay, Relay Coordination
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 21 Nov 2025 05:13
Last Modified: 21 Nov 2025 05:13
URI: https://repository.itpln.ac.id/id/eprint/4026

Actions (login required)

View Item
View Item