WIBOWO, WIDIANTO and Sampurno, Sampurno (2018) STUDI KOORDINASI SISTEM PROTEKSI INTERBUS TRANSFORMER 2 500/150 KV 500 MVA GITET CAWANG BARU. Diploma thesis, ITPLN.
Skripsi Widianto Wibowo 2013-11-291.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Transformator daya pada subsistem penyaluran tenaga listrik merupakan suatu peralatan yang penting untuk menyalurkan daya listrik, sehingga harus diproteksi dari adanya gangguan yang menyebabkan kehandalan dari trafo tersebut menurun. Interbus Transformer merupakan peralatan penting pada gardu induk yang perlu di proteksi dari gangguan yang sering terjadi. Untuk mengetahui setelan rele proteksi yang terpasang, maka perlu dilakukan perhitungan dengan adanya simulasi gangguan hubung singkat. Studi ini mengambil lokasi penelitian di GITET Cawang Baru dengan subjek penelitian IBT 2 500/150 kV 500 MVA. Dari perhitungan didapatkan besarnya arus hubung singkat satu fasa ke tanah sebesar 6.374,41 A pada sisi 150 kV dan 16.836,17 A pada sisi 500 kV. Untuk arus hubung singkat tiga fasa sebesar 7.049,82 A pada sisi 150 kV dan 24.056,25 A pada sisi 500 kV. Berdasarkan hal tersebut, perlu dilakukan penyetelan rele ideal yang dapat memproteksi trafo dari gangguan. Koordinasi rele ketika terjadi gangguan, selain membutuhkan setelan rele ideal, juga membutuhkan setelan waktu yang tepat agar rele yang terpasang dapat bekerja dimanapun terjadi gangguan.
The power transformer to power supply subsystem is an important things for power supply, so it must be protected from some interferences that may cause the reliability of the transformer to decrease. The interbus transformer is one of high voltage substation’s important device that should be pretected from disturbance that often happened. To knowing the installed protecton relay’s setting, then it needs to do calculating with short circuit dirturbance’s simulation. In this study, taking GITET Cawang Baru as the research location and the IBT 2 500/150 kV 500 MVA as the research subject. From calculating, obtained the amount of short circuit line to netral current of 6.374,41 A at 150 kV side and 16.836,17 A at 500 kV side. For line to line short circuit current of 7.049,82 A at 150 kV side and 24.056,25 A at 500 kV side. Based on that data, needed to be done the ideal setting that can protected the transformer from the disturbance. Relays’s coordination when the disturbance occurs, either needed the ideal setting, also need the precision time setting so that the installed relays can protecting wherever the disturbance occurs.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Interbus Transformer, Rele, Gangguan Hubung Singkat. Interbus Transformer, Relay, Short Circuit Disturbance. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |