RESTUWANGI, RIMA ISYANA and Susanto, djoko (2017) ANALISA JATUH TEGANGAN PADA JARINGAN TEGANGAN MENENGAH PENYULANG E2 DI GARDU INDUK EMBALUT TENGGARONG. Diploma thesis, ITPLN.
cover sampai daftar lampiran.pdf
Download (148kB)
BAB 1- BAB 5 yang sudah di revisi sidang.pdf
Restricted to Registered users only
Download (2MB)
Daftar Pustaka.pdf
Download (57kB)
daftar riwayat hidup rima.pdf
Download (48kB)
Abstract
Suatu sistem tenaga listrik yang baik harus memiliki nilai tegangan yang tidak melebihi batas toleransi serta rugi-rugi daya yang kecil. Batas toleransi yang diperbolehkan untuk suatu nilai tegangan ( +5% ; -10% ) dari nilai nominalnya. Nilai tegangan yang konstan akan mengoptimalkan unjuk kerja dari peralatan listrik yang digunakan oleh konsumen. Sedangkan rugi-rugi daya yang kecil akan menjaga pasokan daya listrik sesuai dengan kebutuhan konsumen, serta dapat mengurangi kerugian finansial yang terjadi selama proses transmisi dan distribusi. Pada skripsi ini akan dilakukan studi untuk perbaikan kualitas tegangan pada jaringan distribusi dengan merekonfigurasi jaringan. Proses perbaikan yang dilakukan pada jaringan tegangan menengah dengan membuka atau menutup Fuse Cut Out , Load Break Switch, Disconnecting Switch, menambah gardu sisipan, dan merubah posisi Tap Changer Proses agar memberikan nilai perbaikan yang paling optimal. Perbaikan tegangan pada skripsi ini disimulasikan dengan menggunakan perangkat lunak ETAP 12.6.0. Dari hasil simulasi tersebut akan didapatkan perbaikan tegangan yang paling optimal yaitu pada studi kasus 1 pada bus yang paling ujung yaitu Bus GRA 706 dengan tegangan 16,12 kV, studi kasus 2 tegangan naik menjadi 19,66 kV dan studi kasus 3 tegangannya menjadi 19,661 Kv.
A good electric power system must have a voltage value that does not exceed the tolerance limit and small power losses. The tolerable limit for a voltage value (+ 5%; -10%) of its nominal value. A constant voltage value will optimize the performance of the electrical equipment used by the consumer. While the small power losses will keep the power supply in accordance with the needs of consumers, and can reduce financial losses that occur during the transmission and distribution process. In this thesis will be a study to improve the quality of stress on the distribution network by reconfiguring the network. The process of repair is done on medium voltage network by opening or closing Fuse Cut Out, Load Break Switch, Disconnecting Switch, adding substation insertion, and change the position of Process Tap Changer to provide the most optimum repair value. Improved voltage on this thesis is simulated using ETAP 12.6.0 software. From the simulation results will be obtained the most optimal voltage improvement is in the case study 1 on the most bus end of the Bus GRA 706 with a voltage of 16.12 kV, case study 2 voltage rose to 19.66 kV and case study 3 voltage to 19,661 kV.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Rekonfigurasi Jaringan, Jatuh Tegangan dan Pembebanan Transformator yang Optimal Network Reconfiguration, Voltage drop and Optimal Transformer loading |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 26 Nov 2025 07:38 |
| Last Modified: | 26 Nov 2025 07:38 |
| URI: | https://repository.itpln.ac.id/id/eprint/4109 |