STUDI ASESMEN KABEL 20 kV BERDASARKAN PARTIAL DISCHARGE

Muslihin, Irsyad and Soewono, Soetjipto (2018) STUDI ASESMEN KABEL 20 kV BERDASARKAN PARTIAL DISCHARGE. Diploma thesis, ITPLN.

[thumbnail of 1. COVER.pdf] Text
1. COVER.pdf

Download (62kB)
[thumbnail of 2. PENGESAHAN sd ABSTRAK.pdf] Text
2. PENGESAHAN sd ABSTRAK.pdf

Download (174kB)
[thumbnail of 3. Bab 1-5 revisi.pdf] Text
3. Bab 1-5 revisi.pdf
Restricted to Registered users only

Download (2MB)
[thumbnail of 4. RIWAYAT HIDUP & ABSEN.pdf] Text
4. RIWAYAT HIDUP & ABSEN.pdf

Download (90kB)
[thumbnail of 5. DAFTAR PUSTAKA.pdf] Text
5. DAFTAR PUSTAKA.pdf

Download (48kB)

Abstract

Perkembangan teknologi dari tahun ke tahun semakin meningkat dengan pesat, tentunya perkembangan teknologi harus dibarengi dengan peningkatan penyediaan tenaga listrik. Di dalam penyediaan tenaga listrik, dari listrik di bangkitkan hingga sampai ke pelanggan dapat disalurkan melalui hantaran udara maupun kabel. Di kota besar seperti Jakarta umumnya saat ini telah banyak digunakan kabel yang ditanam di dalam tanah. Kabel ini biasa disebut dengan Saluran Kabel Tegangan Menengah (SKTM). Seiring dengan perkembangan teknologi maka perlu untuk meningkatkan kualitas penyaluran tenaga listrik, yaitu dengan diperlukan adanya asesmen kabel tegangan menengah 20 kV. Manfaat dari asesmen kabel adalah untuk menjaga penyaluran tenaga listrik yang handal, terutama di daerah padat penduduk dan padat aktivitas, karena perlu untuk mendeteksi kondisi kabel yang beroperasi dalam jangka waktu tertentu. Demi menjamin kehandalan penyaluran energi listrik pada sistem kabel tersebut maka diperlukan suatu sistem diagnosa kondisi kabel yang dapat mengetahui kondisi kabel di lapangan. Berdasarkan pengukuran Partial Discharge dengan menggunakan metode Oscillating Wave Test System (OWTS) yang mana dalam pengujiannya dapat melihat pemetaan posisi Partial Discharge, yang selanjutnya dapat ditentukan kondisi kabel dalam keadaan baik atau buruknya sehingga menjadi pedoman dalam metode pemeliharaan pada kabel tanah yang akan dilakukan.

Technological developments from year to year increasing by leaps and bounds, of course, the development of technology should be coupled with an increase in the supply of electricity. In the electric power supply, of electricity raised up to the customer can be routed over the air or cable conduction. In big cities such as Jakarta in general is now widely used cables buried in the ground. This cable is commonly called the Saluran Kabel Tegangan Menengah (SKTM). Along with technological developments it is necessary to improve the quality of electrical power, which is necessary to assess the medium voltage 20 kV cables. Benefits of the assessment was to keep the cable distribution of electric power that is reliable, especially in densely populated areas and dense activity, because it is necessary to detect the cable operating conditions within a certain period. To ensure the reliability of distribution of electrical energy in the cable system, we need a system that can diagnose wiring conditions determine the condition of the cable in the field. Based on Partial Discharge measurements using the Oscillating Wave Test System (OWTS) which in the test can see the position mapping Partial Discharge, which can then be determined condition of the cable is in good condition or bad that guide the method of raising the ground cable will do.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Saluran Kabel Tegangan Menengah (SKTM), Partial Discharge, Oscillating wave test system (OWTS) Saluran Kabel Tegangan Menengah (SKTM) Partial Discharge, Oscillating Wave Test System (OWTS)
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 26 Nov 2025 13:18
Last Modified: 26 Nov 2025 13:18
URI: https://repository.itpln.ac.id/id/eprint/4118