Nizami, Farhan and Suyanto, Heri (2017) SETTING KOORDINASI OVER CURRENT RELAY (OCR) DI PT. PLN (PERSERO) DISTRIBUSI KALIMANTAN BARAT AREA SANGGAU DENGAN METODA SIMULASI. Diploma thesis, Institut Teknologi PLN.
COVER.pdf
Restricted to Registered users only
Download (25kB)
Skripsi FIX.pdf
Restricted to Registered users only
Download (2MB)
LAMPIRAN Grafik setting relay.pdf
Restricted to Registered users only
Download (207kB)
LAMPIRAN LEMBAR KONSULTASI PEMBIMBING.pdf
Restricted to Registered users only
Download (781kB)
LAMPIRAN SETTING RELAY.pdf
Restricted to Registered users only
Download (24kB)
LAMPIRAN SINGLE LINE DIAGRAM.pdf
Restricted to Registered users only
Download (196kB)
Abstract
Di dalam jaringan distribusi 20 kV sering terjadi gangguang, salah satunya adalah gangguan arus hubung singkat. Dalam mengatasi gangguan arus hubung singkat ini diperlukan koordinasi antar pengaman jaringan distribusi agar dapat mengisolasi gangguan dan melindungi jaringan distribusi serta perlatan yang berada di jaringan tersebut. Rele arus lebih – OCR memproteksi instalasi listrik terhadap gangguan antar fasa. Prinsip kerja OCR, yang membedakan hanyalah pada fungsi dan elemen sensor arus. OCR biasanya memiliki 2 atau 3 sensor arus (untuk 2 atau 3 fasa). Rele ini bekerja dengan membaca input berupa besaran arus kemudian membandingankan dengan nilai setting, apabila nilai arus yang terbaca oleh rele melebihi nilai setting, maka rele akan mengirim perintah trip (lepas) kepada Pemutus Tenaga (PMT) atau Circuit Breaker (CB) setelah tunda waktu yang diterapkan pada setting. Waktu kerja rele OCR tergantung nilai setting dan karakteristik waktunya. Elemen tunda waktu pada rele ini pada 2, yaitu elemen low set dan elemen high set. elemen low set bekerja ketika terjadi gangguan dengan arus hubungsingkat yang relative kecil, sedangkan elemen high set bkerja ketika terjadi gangguan dengan arus hubung singkat yang cukup besar. Rele OCR dipasang sebagai alat proteksi motor, trafo, penghantar transmisi, dan penyulang. Dilakukan perhitungan dan analisis ulang dengan merubah penyetelan Rele arus lebih di sisi penyulang menggunakan karakteristik invers sesuai dengan ketentuan PLN.
In the distribution network of 20 kV frequent disturbance, one of them is short circuit current interruption. In overcoming this short circuit current interference is required coordination between the safety of the distribution network in order to isolate the disturbance and protect the distribution network and equipment residing in the network. Overcurrent Rele - OCR protects electrical installations against inter-phase noise. The working principle of OCR, which distinguishes only on the functions and elements of current sensors. OCR usually has 2 or 3 current sensors (for 2 or 3 phase). This rele works by reading the input in the form of a current value and then comparing it with the setting value, if the current value read by the release exceeds the setting value, the rele will send trip command to the Circuit Breaker (CB) after the time delay Which is applied to settings. OCR release time depends on setting value and time characteristics. Time delay element in this release at 2, ie low set element and high set element. Low set elements work when interference occurs with relatively small short-circuit current, while high-performance elements work when interference with large short-circuit current occurs. OCR Rele is installed as a motor protection device, transformer, transmission carrier, and repeater. Perform calculations and re-analysis by changing the adjustment of the overcurrent currents on the side of the buffer using the inverse characteristics in accordance with the provisions of PLN.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | hubung singkat, OCR, rele arus lebih short circuit, OCR, more current relay |
| Subjects: | Bidang Keilmuan > Electrical Engineering Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Budi Herdiansyah |
| Date Deposited: | 27 Nov 2025 02:09 |
| Last Modified: | 27 Nov 2025 02:09 |
| URI: | https://repository.itpln.ac.id/id/eprint/4135 |
