Arighy, Nahdathul and Hariyanto, Agung (2017) KOORDINASI KERJA RELE OCR GFR PADA GI SATUI SEHUBUNGAN DENGAN BEROPERASINYA PLTBm TANAH BUMBU DI KALIMANTAN SELATAN. Diploma thesis, ITPLN.
HALAMAN JUDUL.pdf
Download (18kB)
awal.pdf
Download (289kB)
DAFTAR ISI skripsi.pdf
Download (212kB)
abstrak indo-inggris.pdf
Download (14kB)
bab I.pdf
Download (18kB)
BAB II.pdf
Download (687kB)
BAB III.pdf
Restricted to Registered users only
Download (349kB)
BAB IV.pdf
Restricted to Registered users only
Download (686kB)
Daftar Pustaka.pdf
Download (8kB)
lembar bimbbingan.pdf
Download (197kB)
Abstract
Tenaga listrik merupakan salah satu kebutuhan pokok saat ini. Oleh karena itu penyediaan energi listrik harus tersedia secara ekonomis dengan memperhatikan mutu. Baik tegangan maupun arus dan freekuensinya serta keandalan. Sistem tenaga listrik tidak pernah lepas dari adanya gangguan hubung singkat yang menyebabkan terganggunya penyaluran daya listrik ke pelanggan. Untuk itu diperlukan koordinasi proteksi pada sisi incoming dan outgoing. Koordinasi proteksi adalah pemilihan alat pelindung dan menentukan setelan waktu guna menentukan daerah perlindungan akibat adanya gangguan hubung singkat. Manfaat dari koordinasi proteksi ini adalah untuk meminimalisir waktu dan daerah gangguan sehingga gangguan yang timbul dapat ditangani dengan cepat dan tidak meluas ke daerah lain yag tidak mengalami gangguan. Pada skripsi ini akan membahas tentang hasil dari koordinasi proteksi disisi incoming dan outgoing akibat masuknya pembangkit listrik tenaga biomassa untuk menyuplai GI satui di daerah kalimantan selatan. Penyettingan ulang rele OCR dan GFR dikarenakan besarnya arus hubung singkat yang terjadi penyulang mengalami kenaikan ketika PLTBm masuk ke sisi jaringan 20 kV.
Electric power is currently one of the main necessity , therefore the electricity supply must be available economically by taking into account the quality either the voltage or electric current and its frequency and also reliability. The electricity system can not be separated from short circuit fault which might result interference in electricity supply to the customer. So that it is required a protection coordination on the incoming and outgoing side. The protection coordination shall include protection tools selection and determining time setting to decide the protection area as a result of short circuit fault. The benefit of protection coordination are minimize the time and disrupting area so that the disturbance occurs can be handle quickly and not spreading to the other area which are not affected with this disturbance. This research will discuss on the result of protection coordination at incoming and outgoing side as a result of biomass powered electricity to suplai GI satui in south Kalimantan. Reconfiguration OCR GFR relay because the amount of short-circuit current that occurs during the feeder increases when the biomass powerplant into the network side of 20 kV.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Koordinasi proteksi, Proteksi,Arus hubung singkat protection coordination, protection, short circuit |