ANALISIS KEGAGALAN PARTIAL DISCHARGE PADA GAS INSULATED SWITCHGEAR (GIS) DENGAN METODE ACOUSTIC INSULATION ANALYZER (AIA)

Santana, Andhika Ary and Soewono, Soetjipto (2017) ANALISIS KEGAGALAN PARTIAL DISCHARGE PADA GAS INSULATED SWITCHGEAR (GIS) DENGAN METODE ACOUSTIC INSULATION ANALYZER (AIA). Diploma thesis, ITPLN.

[thumbnail of SKRIPSI ANDHIKA.pdf] Text
SKRIPSI ANDHIKA.pdf
Restricted to Registered users only

Download (6MB)

Abstract

Gas Insulated Switchgear (GIS) telah lama dan banyak digunakan dalam system kelistrikan di Indonesia. Untuk GIS yang menggunakan isolasi SF6 seperti GIS ketapang dan Gedung pola maka partial discharge akan terjadi seiring dengan bertambahnya umur serta beberapa faktor lain yang mempengaruhi isolasi tersebut. Berdasarkan hasil uji yang dilakukan pada GIS ketapang dan GIS gedung pola, di dapatkan nilai PD dengan nilai dibawah standar CIGRE (<5 mV), sehingga dapat disimpulkan GIS ketapang dan GIS gedung pola masih dalam keadaan baik. Partial discharge menghasilkan tiga bentuk energi yaitu elektromagnetik, akustik, dan gas. Oleh karena itu Salah satu cara untuk mengidentifikasi dan mengetahui letak atau lokasi dari partial discharge pada isolasi SF6 dalam GIS ialah dengan menggunakan metode AE (Acoustic Emission) dari alat Acoustic Insulation Analyzer (AIA). Menggunakan alat tersebut dapat diketahui apakah isolasi SF6 dan peralatan-peralatan GIS tersebut masih layak digunakan atau tidak.

Gas Insulated Switchgear (GIS) has been long and widely used in electrical systems in Indonesian. For GIS using SF6 isolation such as GIS ketapang and gedung pulo then partial discharge will occur along with increasing age and some other factors that influence the such isolation. Based on the results of tests conducted on GIS ketapang and GIS gedung pola, in obtaining PD value under the value of CIGRE (<5 mV), so it can be concluded GIS ketapang and GIS gedung pulo is still in good condition. Partial discharge produces three forms of energy : electromagnetic, acoustic, and gas. Therefore One way of identifying and knowing the location or location of the partial discharge on SF6 isolation in GIS is by using the AE (Acoustic Emission) method of Acoustic Insulation Analyzer (AIA). Using the tool can be known whether the SF6 isolation and GIS equipment is still feasible to use or not

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Isolasi SF6, Partial Discharge, Gas Insulated Switchgear (GIS), nilai Isolation SF6, Partial Discharge, Gas Insulated Switchgear (GIS), value
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 30 Nov 2025 15:24
Last Modified: 30 Nov 2025 15:24
URI: https://repository.itpln.ac.id/id/eprint/4222