Manurung, Mayesti Margharetta and Susanto, djoko (2017) ANALISA PERUBAHAN POSISI TAP PADA OLTC TRANSFORMATOR 60 MVA 150/20kV GARDU INDUK MUARA KARANG BARU. Diploma thesis, ITPLN.
PEMBUKAAN (1).pdf
Restricted to Registered users only
Download (1MB)
Abstract
Salah satu masalah yang terdapat dalam sistem tenaga listrik adalah perubahan atau penurunan tegangan yang sering kali terjadi di dalam penyaluran tenaga listrik. Untuk mengantisipasi tegangan keluaran yang berubah-ubah, transformator utama di Gardu Induk Muara Karang Baru di lengkapi dengan pengubah sadapan berbeban (OLTC = On Load Tap Changer) yang bekerja terhadap setiap perubahan beban dan tegangan sisi primernya sehingga tetap terjaga agar tegangan yang di inginkan tetap konstan. Besar tapping tegangan OLTC transformator sebesar 1,25% dari tegangan nominal. Pada posisi tap 11 dengan rasio 7,312:1 dan tegangan sisi primer tertinggi 149 kV maka sisi sekunder 20,102 kV, begitu juga pada keadaan posisi tap 10 ,dengan rasio 7,403:1 dan tegangan sisi primer tertinggi 154 kV ,maka sisi sekunder 21,8 kV.Bila beban meningkat ,alat pengatur tegangan ini akan menaikan tegangan dengan mengatur sadapan transformator sisi tegangan tinggi, guna mengatasi jatuh tegangan sisi sekunder transformator.
One of the problems in the electric power system is the change or decrease in voltage that often occurs in the supply of electricity. To anticipate the varying output voltage, the main transformer of the new reefestuary is equipped with On Load tap changer , acting on each load change and the primary side voltage so as to keep the desired voltage constant. Large tapping voltage OLTC transformer 1,25% of nominal voltage. At the tap position 11 with the ratio 7,312:1 and the highest primary side 149 kV , the secondary side of 20,102 kV as well as in the position state tap 10 with the ratio 7,403:1 and highest primary side is 154 kV, the secondary side is 21,8 kV. When the load increases, the voltage regulator will increase the voltage by adjusting the ;lead side transformer voltage, to overcome the voltage drop of the secondary side of the transformer.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator , Pengubah sadapan berbeban (On Load Tap Changer) , Beban. Transformer, Load converter leads (On Load Tap Changer), Load. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 01 Dec 2025 04:11 |
| Last Modified: | 01 Dec 2025 04:11 |
| URI: | https://repository.itpln.ac.id/id/eprint/4255 |