KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG MADYA GARDU INDUK TIGA RAKSA

Sitorus, Mika Polin and Prianda, Prianda (2017) KOORDINASI RELE ARUS LEBIH DAN RELE GANGGUAN TANAH PADA PENYULANG MADYA GARDU INDUK TIGA RAKSA. Diploma thesis, ITPLN.

[thumbnail of JUDUL .pdf] Text
JUDUL .pdf

Download (88kB)
[thumbnail of Lembar Pengesahan - Gambar.pdf] Text
Lembar Pengesahan - Gambar.pdf

Download (175kB)
[thumbnail of ISI.pdf] Text
ISI.pdf
Restricted to Registered users only

Download (757kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (185kB)
[thumbnail of DAFTAR RIWAYAT HIDUP.pdf] Text
DAFTAR RIWAYAT HIDUP.pdf

Download (86kB)

Abstract

Energi listrik merupakan salah satu kebutuhan pokok saat ini,sehingga tenaga listrik harus tersedia dengan mutu yang baik, oleh karena itu jaringan tegangan menengah memiliki peranan penting dalam pendistribusian tenaga listrik. Dalam kenyataanya gangguan sering terjadi, gangguan utamanya adalah gangguan arus hubung singkat. Gangguan ini dapat menyebabkan kerusakan peralatan listrik sehingga dapat memadamkan sistem secara keseluruhan. Untuk mengatasi hal ini diperlukan sistem proteksi yang sensitif, selektif, cepat, andal dan aman sehingga dapat menghilangkan dan mengurangi dampak gangguan yang terjadi. Jenis proteksi yang digunakan untuk mengatasi arus lebih diantaranya adalah Over Current Relay (OCR) dan Ground Fault Relay (GFR). Rele tersebut bekerja dengan membaca masukan berupa besaran arus kemudian membandingkannya dengan nilai setting. Pada setting rele juga diterapkan waktu tunda agar terjadi koordinasi terhadap rele yang lainnya. Hasil yang didapat membuktikan bahwa dengan menggunakan sistem koordinasi OCR dan GFR yang diterapkan, mampu mengatasi arus hubung singkat pada sistem daya listrik.

Energy is one of the basic needs of life, so power must be provided with good quality. therefore the medium voltage network has an important role in the distribution of electric power. In fact the common disorder, major disruption is short-circuit current interruption. This disorder can cause damage to electrical equipment so that it can extinguish the overall system. To address this caseneed the protection system is sensitive, selective, rapid, reliable and secure so as to eliminate and reduce the impact of disturbance. The type of protection used to overcome is overcurrent Over Current Relay (OCR) and Ground Fault Relay (GFR). The relay works by reading the input of the current magnitude and compared with the value of the setting. In the relay setting is also applied to the time delay that occurs coordination to relay the others. The results proved that by using OCR and GFR coordination system is applied, is able to overcome the short circuit current in the electric power system.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Hubung singkat, rele OCR, rele GFR short-circuit, relay OCR, relay GFR
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro