STUDI PEMASANGAN KAPASITOR BANK PADA PELANGGAN INDUSTRI UNTUK MENGANTISIPASI POTENSI TAGIHAN KVARH

Tanjung, M Fajar and Paryoto, Djoko (2017) STUDI PEMASANGAN KAPASITOR BANK PADA PELANGGAN INDUSTRI UNTUK MENGANTISIPASI POTENSI TAGIHAN KVARH. Diploma thesis, ITPLN.

[thumbnail of COVER.pdf] Text
COVER.pdf

Download (15kB)
[thumbnail of DAFTAR ISI.pdf] Text
DAFTAR ISI.pdf

Download (220kB)
[thumbnail of SKRIPSI PDF.pdf] Text
SKRIPSI PDF.pdf
Restricted to Registered users only

Download (869kB)
[thumbnail of Daftar Pustaka PDF.pdf] Text
Daftar Pustaka PDF.pdf

Download (86kB)
[thumbnail of DAFTAR RIWAYAT HIDUP PDF.pdf] Text
DAFTAR RIWAYAT HIDUP PDF.pdf

Download (16kB)
[thumbnail of Lampiran Lembar konsul.pdf] Text
Lampiran Lembar konsul.pdf

Download (34kB)
[thumbnail of Lampiran Tarif tenaga listrik pdf.pdf] Text
Lampiran Tarif tenaga listrik pdf.pdf

Download (251kB)
[thumbnail of lampiran Tagihan PT Pam Jaya.pdf] Text
lampiran Tagihan PT Pam Jaya.pdf

Download (306kB)
[thumbnail of lampiran single line.pdf] Text
lampiran single line.pdf

Download (95kB)

Abstract

Berdasarkan tarif dasar listrik yang ditetapkan oleh PLN mengenakan biaya untuk pemakaian daya reaktif sekian /kVARh apabila pelanggan memakai kVARh berlebih dan menyebabkan faktor daya cos φ kurang dari 0,85, namun pemakaian kVARh dari pelanggan tergantung dari penggunaan motor motor listriknya sehingga untuk industri dengan pemakaian beban motor yang besar tidak dapat menghindari pembayaran untuk kVARh nya , semakin besar kVARh yang diserap oleh pelanggan maka menyebabkan cos φ atau faktor daya semakin kecil,salah satu untuk mengatasinya dengan memasangan kapasitor , karena daya dipasang kapasitor pemakaian kVARh nya berkurang , jadi dapat memperbaiki cos φ, salah satu untuk mengatasi masalah tersebut adalah dengan memasang sumber daya reaktif kapasitif di dekat beban untuk mengompensasi daya kVARh yang bersifat induktif sehingga cos φ bisa diperbaki, sumber daya reaktif yang digunakan biasanya adalah kapasitor, maka dari itu perlu dilakukan studi pemasangan kapasitor terhadap pelanggan industri untuk mengetahui mana yang lebih menguntungkan antara pemasangan kapasitor atau pembayaran kVARh.

Based on the basic electricity tariff set by PLN charging for the reactive power consumption of kVARh / kVARh if the customer is using excess kVARh and causing power factor cos φ less than 0.85, but kVARh usage from customer depends on the use of electric motor motor so that for industry with usage A large motor load can not avoid paying for its kVARh, the larger the kVARh is absorbed by the subscriber then it causes cos φ or less power factor, one to overcome it by mounting the capacitor, since the installed power of the kVARh capacitor is reduced, so it can repair the cos Φ, one to solve the problem is to install the capacitive reactive power source near the load to compensate the inductive kVARh power so that cos φ can be switched, the reactive power source used is usually the capacitor, therefore it is necessary to study the installation of capacitors to industrial customers to know which is more advantageous between the installation of capacitors or kVARh payments.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: kVARh, Daya reaktif , Daya aktif , Kapasitor kVARh, Reactive power, Active power, Capacitors
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 01 Dec 2025 07:56
Last Modified: 01 Dec 2025 07:56
URI: https://repository.itpln.ac.id/id/eprint/4276

Actions (login required)

View Item
View Item