Abstract

Sistem tenaga listrik merupakan sarana untuk menyalurkan energi listrik dari pembangkit listrik sampai ke peralatan milik konsumen. Salah satu peralatan yang sangat penting dalam penyaluran tenaga listrik yaitu transformator daya. Oleh karena itu, diusahakan agar peralatan ini berusia panjang dan dapat lebih lama dipergunakan. Transformator tenaga didesain dengan suhu sekitar 20C tetapi beroperasi pada suhu lingkungan 30 C di Indonesia, maka trafo tersebut harus disesuaikan pembebanannya. Semakin tinggi suhu setempat semakin pendek operasional dan semakin besar susut umur dari transformator tenaga tersebut. Susut umur transformator dipengaruhi oleh isolasi belitan trafo dan minyak trafo tersebut. Salah satu kerusakan atau kegagalan isolasi dari minyak trafo diakibatkan dari perubahan suhu atau suhu sekitar pada transformator tenaga terendam minyak tersebut. Pemanasan pada belitan trafo dapat mengkibatkan isolasi menjadi rusak dan kenaikan temperatur minyak akan mengubah sifat serta komposisi minyak trafo. Apabila perubahan-perubahan tersebut dibiarkan akan mengakibatkan nilai isolasi dari minyak menurun. Pada skripsi ini meneliti pengaruh pembebanan tranformator tenaga dan pengaruh suhu lingkungan terhadap susut umur dilihat dari penurunan isolasi belitan transformator serta menganalisis susut umur trafo tenaga PLTU Unit 4 Muara Karang dengan mengacu pada pada standar IEC 354 tahun 1972.

Electricity power system is a medium for supply electricity energy from power plants into consumens tool. One of tool that very important for supply electricity power is power transformator. That is why, the tools is must to be in a long age dan can be use for a long time. Operating temperature of potential transformer’s design is 20C. However it is not applicable in Indonesia with temperature 30C. Because of that, the load of the transformer need to be adjusted. Operating lifetime will become shorter and loss of life will become greater at higher temperature. Loss of life of the transformer depends on winding isolation and transformer oil. Overheating in transformer winding can damage the isolation and increase oil temperature resulting in degradation of the oil. If the changes occur in a long period, it can decrease the isolation value of the oil. The final project observes the correlation between load of transformer and ambient temperature to the loss of life viewed from deterioration transformer winding insulation and analyze PLTU Unit 4 Muara KarangTransformer loss of life refer to 1972 IEC 354 standard.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: transformator, susut umur, pembebanan, suhu sekitar. transformer, loss of life, loading, ambient temperature .
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 02 Dec 2025 06:00
Last Modified: 02 Dec 2025 06:00
URI: https://repository.itpln.ac.id/id/eprint/4309

Actions (login required)

View Item
View Item