PERHITUNGAN PERFORMA SEA WATER PUMP SEBELUM DAN SESUDAH CORRECTIVE MAINTANANCE PADA PLTU PELABUHAN TARAHAN 2X8 MW

Kurniawan, Dieky and Rusjdi, Halim and Sulistiyo, Eko (2024) PERHITUNGAN PERFORMA SEA WATER PUMP SEBELUM DAN SESUDAH CORRECTIVE MAINTANANCE PADA PLTU PELABUHAN TARAHAN 2X8 MW. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR_Dieky Kurniawan_202072004 . (1).pdf] Text
PROYEK AKHIR_Dieky Kurniawan_202072004 . (1).pdf
Restricted to Repository staff only

Download (2MB)

Abstract

Tujuan pelaksanaan tugas akhir ini adalah memahami tentang kerja Sea Water Pump dan juga untuk mengetahui performa Sea Water Pumpberdasarkan perhitungan.
Proses pengerjaan Tugas Akhir ini meliputi tiga tahap. Pertama, tahapan persiapan data, kedua, tahapan engumpulan data, ketiga, tahapan pengolahan data. Fluida yang mengalir pada sistem ini adalah air laut. Dari hasil analisa yang dapat disimpulkan bahwa, efisiensi pompa dari tanggal 01-03-2023 jam 22:00 mengalami penurunan performa akibat adanya vibrasi yang mengakibatkan baut – baut pada housing pompa lepas yang menyebabkan kebocoran pada pompa unit 1. Hal ini menyebabkan terendamnya unit pompa sehingga fluida tidak sepenuhnya masuk ke dalam kondensor melainkan keluar melalui housing pompa. Hasil dari analisis ini adalah efisensi pompa tipe 28XG400YFB-A yang bekerja sebesar 95,4% mengalami penurunan efisiensi sebesar 88,7%, disamping itu juga ditemukan terjadinya kavitasi dan vibrasi pada pompa yang menyebabkan kerusakan dan penurunan efisiensi kerja pompa. Oleh sebab itu harus dilakukan Corrective Maintanannce pada pompa unit 1 arah laut agar mengetahui penyebab terjadinya keruakan pada pompa, agar dapat beroprasi kembali seperti semula.

The aim of carrying out this final assignment is to understand the work of the Sea Water Pump and also to determine the performance of the Sea Water Pump based on
calculations. The process of working on this final assignment includes three stages. First, the data preparation stage, second, the data collection stage, third, the data processing stage. Fluid flowing in This system is sea water. And the results of the analysis can be
concluded that, the efficiency of the pump and on 01-03-2023 at 22.00 experienced a decrease in performance due to vibrations which caused the bolts on the pump housing
to come loose which caused a leak in pump unit 1. This caused the pump unit to be submerged so that the fluid was not completely enters the condenser but exits through the
pump housing. The results of this analysis are that the efficiency of the type 28XG400YFB-A pump which works is 95.4%, experiencing a decrease in efficiency of 88.7%, besides that, cavities and vibrations are also found in the pump which causes damage. and decreased pump efficiency Therefore, corrective maintenance must be carried out on the unit 1 seaward pump in order to find out the cause of damage to the pump, so that it can operate again as before.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Sea Water Pump, Submersible Pump, PLTU Maintenance, Pump Efficiency, Cavitation
Subjects: Bidang Keilmuan > Energi dan Ketenagalistrikan
Bidang Keilmuan > Mechanical Engineering
Bidang Keilmuan > Power generation
Bidang Keilmuan > Pump
Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknologi Mesin
Depositing User: Yudha Formanto
Date Deposited: 02 Sep 2025 07:14
Last Modified: 02 Sep 2025 07:14
URI: https://repository.itpln.ac.id/id/eprint/439

Actions (login required)

View Item
View Item