Rahman, Eko and Hajar, Ibnu (2017) KAJIAN PEMASANGAN LIGHTNING ARRESTER PADA SISI HV TRANSFORMATOR DAYA UNIT SATU GARDU INDUK TELUK BETUNG. Diploma thesis, ITPLN.
A.Halaman Judul.pdf
Download (18kB)
C.Pendahuluan.pdf
Download (1MB)
B.ISI.pdf
Restricted to Registered users only
Download (1MB)
D.Lampiran A Daftar Riwayat Hidup.pdf
Download (168kB)
E.Lampiran B Lembar Bimbingan.pdf
Download (288kB)
F.Lampiran C SLD G.I Teluk Betung.pdf
Download (457kB)
Abstract
Umumnya Pusat-pusat listrik terhubung dengan saluran transmisi udara, dan saluran transmisi udara rentan mengalami gangguan yang dipengaruhi dari luar sistem, salah satunya adalah sambaran petir. Sambaran petir berbahaya bagi komponen-komponen yang terdapat pada pusat listrik. Dan oleh karena itu diperlukannya proteksi dari sambaran petir tersebut, agar komponen pada pusat listrik tidak mengalami kerusakan pada saat terkena surja petir. Pada penelitian ini dibahas proteksi transformator daya (60MVA) pada gardu induk teluk betung agar transformator daya tersebut aman dari tegangan lebih yang disebabkan oleh surja petir. Spesifikasi arrester yang terpasang pada sisi HV transformator daya unit satu gardu induk Teluk Betung dengan tegangan nominal 144 kV, telah sesuai dengan kebutuhan sistem. Jarak maksimum antara arrester dan transformator daya yang diperbolehkan adalah 28,5 meter. Jarak dilapangan adalah 3 meter, tegangan yang tiba pada transformator daya adalah 480 kV dan masih dibawah nilai tingkat isolasi dasar trafo, sehingga perlindungan transformator daya terhadap surja petir sudah sangat baik.
Generally The power centers are connected to the air transmission line, and the airborne transmission channel is susceptible to disturbances that are affected from outside the system, one of which is a lightning strike. Lightning strikes are harmful to the components present in the central power supply. And therefore, the protection from the lightning strikes is required, so that the components in the power center is not damaged when exposed to lightning surges. In this research we discussed the power transformer protection (60MVA) on the Teluk Betung substation so that the power transformer is safe from the over voltage caused by the lightning surge. The specification of the arresters mounted on the HV side of the power transformer unit one of Teluk Betung substation with nominal voltage of 144 kV has been in accordance with the system requirements. The maximum distance between the arrester and the allowable power transformer is 28.5 meters. Distance in the field is 3 meters, the voltage that arrives at the power transformer is 480 kV and still below the Basic insulation level of the transformer, so that the protection of the power transformer against the lightning surge is very good.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Surja Petir, Lightning Arrester, Gardu Induk Teluk Betung. Lightning Surge, Lightning Arrester, Teluk Betung Substation. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |