Pintubatu, Sri Armaya Margaretha and Willy, Purnomo (2017) STUDI PENGGUNAAN RELE DIFERENSIAL PADA JARINGAN DISTRIBUSI SISTEM LOOP DI MEGA KUNINGAN. Diploma thesis, ITPLN.
LAMPIRAN-LAMPIRAN.pdf
Download (208kB)
BAB I - V.pdf
Restricted to Registered users only
Download (1MB)
DATA PANJANG PENYULANG ZDT.pdf
Download (128kB)
Abstract
Jaringan distribusi khususnya di kota-kota besar seperti Jakarta berkembang menjadi jaringan kabel tanah, berkaitan dengan masalah izin dari Pemerintah Daerah. Penggunaan kabel tanah dalam jaringan distribusi memberikan masalah operasionil sebagai seperti Kabel tanah jarang mengalami gangguan, namun apabila terjadi gangguan proses untuk mencari titik gangguan memakan waktu yang cukup lama, bisa sampai beberapa hari. Gangguan pada kabel tanah umumnya terjadi karena ada kerusakan pada kabel tanah. Perbaikan kerusakan ini juga memakan waktu yang lama, kira-kira 1 hari. Mengingat hal-hal tersebut di atas ada pemikiran untuk menggunakan rele diferensial dalam jaringan distribusi yang menggunakan kabel tanah dan konfigurasi kabel dibuat loop sehingga keandalannya menjadi lebih baik. Dalam skripsi ini akan dibahas penggunaan rele diferensial saat gangguan berada pada kabel tanah antara gardu distribusi KN32 dan KN36 dengan menggunakan perhitungan analisis hubung singkat pada jaringan distribusi sistem loop. Nilai arus gangguan hubung singkat pada kabel tanah tersebut adalah 283,12 A dan arus setting rele diferensial sebesar 0,649A.
The network distribution especially in big cities such as Jakarta develops into a ground cable networks, it was due to the issue of permission from the Regional Government. The using of ground cable in network distribution caused some operational problems like ground cable is rarely disturbed, however if there is a disturbance, the process to find the disturbance point takes a long times, it can be up to several days. Ground cable disturbance mostly happen because of the ground cable was broken. The reparation also takes a long times, about 1 day. Because of those considerations, there is a thought of using differential relay in network distribution, which is use ground cable and the cable configuration is made into loop system so that its reliability becomes better. This thesis will study the used of differential relay when disturbance occur to the ground cable between relay station distribution KN32 and KN36 by using calculation of analysis of short circuit in distribution network loop system. The value of current disturbance in the ground cable is 238,12A and current setting relay differential is 0,649A.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Jaringan distribusi, rele diferensial, sistem loop. network distribution, differential relay, loop system. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 04 Dec 2025 10:25 |
| Last Modified: | 04 Dec 2025 10:25 |
| URI: | https://repository.itpln.ac.id/id/eprint/4407 |