Rifaldi, Mukhamad Dwi and Soewono, Soetjipto (2018) STUDI DIAGNOSIS PARTIAL DISCHARGE PADA GAS INSULATED SWITCHGEAR 150 KV PULO GADUNG DENGAN METODE AKUSTIK. Diploma thesis, ITPLN.
SKRIPSI MUKHAMAD DWI RIFALDI (2013-11-029).pdf
Restricted to Registered users only
Download (2MB)
Abstract
Semakin berkembangnya perkotaan membuat lahan-lahan semakin sempit, sehingga muncul metode lain dalam pembangunan Gardu Induk supaya tidak perlu membutuhkan lahan yang luas khususnya di pusat kota. Ada metode Gardu Induk Berisolasi Gas atau biasa disebut GIS (Gas Insutaled Substation) . GIS merupakan bentuk pengembangan gardu induk, GIS belakangan ini banyak digunakan dalam sistem ketenagalistrikan dikarenakan kelebihan-kelebihannya dibandingkan tipe gardu induk konvensiaonal. Karena itu, berbagai gangguan masih mungkin terjadi di dalam kompartemen GIS. Maka dilakukan diagnosis untuk mengetahui parameter gas SF6 pada GIS salah satunya adalah partial discharge. Pada skripsi ini diagnosis akan menggunakan metode akustik untuk mengetahui adanya partial discharge pada kompartemen-kompartemen GIS. Dari hasil diagnosis dengan metode inilah akan ditentukan kondisi dari isolasi GIS tersebut. Dari pengujian partial discharge pada kompartemen PMT ditemukan nilai rata-rata PD 0,43 ini adalah nilai GIS yang baik sebab jauh di bawah standar CIGRE yaitu <5 pC dan IEC <10 pC. Serta ditemukan pula nilai rata rata PD yang melewati standar yaitu 9,61 pC. Maka dilakukanlah perbaikan pada GIS tersebut agar dapat kembali normal.
The growth of urban areas made of land narrower, so now appears the other methods in the development of the main stations that don’t need to require extensive land especially in the middle of city. There is a method called GIS (Gas Insutaled Substation) . GIS is a form of the development of the Substation GIS lately is many used in electrical systems due to it is advantages compared to conventiaonal substations type. Because of that, various disturbance could still occur in the GIS compartment. It is done diagnosis to know the parameters of gas SF6 on GIS one is partial discharge. In this bachelor theses diagnosis will use the acoustic method to know the existence of partial discharge on the GIS compartment. From the results of the diagnosis with this method will be determined the condition of the GIS isolation. From the testing partial discharge on CB compartment found the value of the average PD is 0,43 pC this is the value of the GIS is good for far below the standard of CIGRE <5 pC and IEC <10 pC. And also found the value of the average PD that passes through the standard 9,61 pC. Then acted accordingly improvements to the GIS in order to return to be normal.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Gardu Induk Berisolasi Gas, Partial Discharge, Metode Akustik Gas Insulated Switchgear, Partial Discharge, Acoustic Method |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 05 Dec 2025 03:36 |
| Last Modified: | 05 Dec 2025 03:36 |
| URI: | https://repository.itpln.ac.id/id/eprint/4409 |