STUDI KOORDINASI RELE ARUS LEBIH,RELE HUBUNG TANAH DAN PENUTUP BALIK OTOMATIS PADA PENYULANG KONSUMEN DI GARDU INDUK PASAR KEMIS

Nugraha, Muhammad Irfan and Rusli, Muhammad (2019) STUDI KOORDINASI RELE ARUS LEBIH,RELE HUBUNG TANAH DAN PENUTUP BALIK OTOMATIS PADA PENYULANG KONSUMEN DI GARDU INDUK PASAR KEMIS. Diploma thesis, ITPLN.

[thumbnail of M. Irfan Nugraha.pdf] Text
M. Irfan Nugraha.pdf
Restricted to Registered users only

Download (6MB)

Abstract

Penyulang konsumen di lengkapi peralatan proteksi over current relay ,ground fault relay. Yang terpasang penutup balik otomatis,peralatan ini berfungsi sebagai proteksi pada sistem distribusi, karena sistem distribusi tegangan menengah memiliki area yang luas dan dekat dengan pelanggan sehingga rentan terjadi gangguan-gangguan yang dapat menyebabkan terganggunya sistem distribusi. Gangguan saluran udara pada jaringan distribusi bersifat temporer dan permanen, namun sebagian besar bersifat temporer. Lebih dari 70% gangguan temporer terjadi saluran udara. Penelitian ini menggunakan metode kuantitatif. Maka dari itu digunakan proteksi PBO dan dikoordinasikan dengan rele OCR dan GFR pada incoming dan outgoing penyulang. Di karenakan adanya sistem proteksi tersebut maka perlu adanya koordinasi proteksi yang selektif,agar memperbaiki kinerja dari sistem proteksi tersebut. Adapun hasil setting yang didapat di GI Pasar Kemis untuk penyulang Konsumen arus hubung singkat 3 fasa OCR incoming tms=0.262, OCR outgoing tms=0.396, PBO 1 tms=0.355 dan PBO 2 tms=0.196. Pada arus hubung singkat 1 fasa ke tanah GFR incoming tms=0.452, GFR outgoing tms=0.324, PBO 1 tms=0.214 dan PBO 2 tms=0.107.

Konsumen feeders equipped with over current relay protection equipment, ground fault relay. Installed automatic return cover , this equipment functions as protection in a distribution system, because the medium voltage distribution system has a large area and is close to the customer so that disturbances occur that can cause disruption of the distribution system. Airway interference in the distribution network is temporary and permanent, but most are temporary. More than 70% of temporary disturbances occur in the airways. This study uses quantitative methods. Therefore PBO protection is used and coordinated with OCR and GFR relay on incoming and outgoing feeders. Due to the existence of the protection system, there is a need for selective protection coordination, in order to improve the performance of the protection system. The results of the settings obtained at Pasar Kemis GI for Consumer feeders for incoming shortcircuit 3 OCR phases tms = 0.262, OCR outgoing tms = 0.396, PBO 1 tms = 0.355 and PBO 2 tms = 0.196. At 1 phase short circuit to ground GFR incoming tms = 0.452, GFR outgoing tms = 0.324, PBO 1 tms = 0.214 and PBO 2 tms = 0.107.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Penutup Balik Otomatis , rele arus lebih, rele hubung tanah. Automatic Flip Cover (PBO), overcurrent relay (OCR), ground connection relay (GFR).
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 05 Dec 2025 03:32
Last Modified: 05 Dec 2025 03:32
URI: https://repository.itpln.ac.id/id/eprint/4421