TOBING, SHEYLIN WIMORA LUMBAN and Willy, Purnomo (2017) ANALISIS RELE DIFFERENSIAL PADA GENERATOR PLTU UJP BANTEN 3 LONTAR UNIT 1 x 315 MW. Diploma thesis, ITPLN.
LEMBARAN TAMBAHAN (JUDUL,DLL).pdf
Download (363kB)
BAB I.pdf
Download (166kB)
BAB II.pdf
Download (828kB)
BAB III.pdf
Restricted to Registered users only
Download (775kB)
BAB IV.pdf
Restricted to Registered users only
Download (597kB)
BAB V.pdf
Restricted to Registered users only
Download (271kB)
Abstract
Generator merupakan peralatan utama dari sistem pembangkitan yang memiliki memilliki karakteristrik pengoperasiaan dan sistem proteksi yang berbeda. Gangguan saat beroperasinya generator diantaranya arus gangguan hubung singkat satu fasa ke tanah dan hubung singkat tiga fasa yang merupakan hubung singkat terbesar. Untuk menghindari gangguan tersebut diperlukannya sistem proteksi yaitu salah satunya menggunakan rele differensial. Rele differensial ini bekerja dengan sangat cepat dan tidak memerlukan penundaan waktu (time delay). Tujuan penelitian ini adalah untuk menganalisis penyetelan rele differensial pada generator di PLTU Banten 3 Lontar yang berpengaruh terhadap keandalan pembangkit dan mendapatkan ukuran arus yang mengalir pada rele differensial. Metode yang digunakan pada penelitian ini adalah metode studi pustaka, metode wawancara dan metode observasi, pengumpulan dan analisa data. Setelan rele differensial secara perhitungan adalah 0,3 A sedangkan hasil pengujian 0,46 A.
Generator is the main part tool of generation system which has different characteristics in the protection system and operation. Some failures that occur during the generator operation are single phase-to-earth short circuit failure, and three phases short circuit failure which is the highest level of short circuit failure. To avoid those failures, a protection system is needed one of which is using differential relay. Differential relay operates really fast and does not need time delay. The purpose of this thesis is to analyze the differential relay setting of the generator in PLTU Banten 3 Lontar affecting the power generation stability, and to calculate the amount of conducted current on differential relay. Methods used in this thesis are literature review, interview and observation, data collection and analysis.The calculation of differential relay setting is 0.3 A while 0.46 A is the test result.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Generator, Rele Differensial, Arus, Hubung Singkat Generator, Differential Relay, Current, Short Circuit. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 05 Dec 2025 03:52 |
| Last Modified: | 05 Dec 2025 03:52 |