AGGATHI, ARINI and Susanto, djoko (2017) ANALISA KEANDALAN TRANSFORMATOR BERDASARKAN MUTU MINYAK TRANSFORMATOR MELALUI PENGUJIAN DISSOLVED GAS ANALYSIS (DGA) PADA PLTU 4 DAN 5 MUARA KARANG. Diploma thesis, ITPLN.
ARINI AGGATHI - 201311001 .pdf
Restricted to Registered users only
Download (2MB)
Abstract
Transformator daya adalah salah satu komponen yang sangat penting dalam penyaluran tenaga listrik dari pembangkitan ke saluran transmisi. Oleh karena itu, dibutuhkan perawatan dan pemeliharaan untuk menghindari kegagalan pada transformator daya, salah satunya dengan melakukan pengujian minyak transformator yaitu pengujian DGA (Dissolved Gas Analysis). Uji DGA merupakan analisis kondisi transformator yang dilakukan berdasarkan jumlah gas terlarut pada minyak transformator. Pada tulisan ini, digunakan dua metode untuk analisa kegagalan transformator yaitu metode Key Gas dan Roger’s Ratio. Dengan menggunakan kedua metode tersebut, maka didapatkan metode yang paling efektif untuk menganalisa kegagalan pada minyak transformator. Setelah didapatkan analisa kegagalan, metode selanjutnya dengan menganalisa Health Index untuk mengetahui kinerja serta kondisi transformator berdasarkan keadaan minyak transformatornya. Metode tersebut dapat menunjukkan kondisi serta kandalan transformator dengan lebih jelas, sehingga dapat mengurangi gangguan serta penanggulangan gangguannya. Penelitian menggunakan dua transformator yang datanya diambil pada tahun 2014, 2015, dan 2016 dengan tujuan untuk mengetahui trend performa agar dapat di evaluasi kinerja serta keandalan kedua transformator tersebut. Hasil yang didapatkan, transformator dalam keadaan yang dapat diterima atau bisa dikatakan baik dengan Indeks Performa sebesar 60%, Dilihat dari hasil yang didapatkan maka tindakan yang dapat dilakukan adalah meningkatkan pengujian/diagnosa pada kedua transformator.
The power transformer is one of the very important components in the electric power distribution from generation to transmission line. Therefore, it takes care and maintenance in order to avoid failures in the power transformer, one of them by doing testing transformer oil testing i.e. DGA (Dissolved Gas Analysis). DGA test is a transformer condition analysis that is done based on the amount of dissolved gases in transformer oil. In this paper, two methods used analysis of the failure of a transformer that are Key Gas method and Roger's Ratio method. By using these two methods, then it brings the most effective method to analyze failure in transformer oil. After the failure of analysis is obtained, the next method is to analyze the Health Index in determining the performance and condition of the transformer based on the transformer oil condition. The method can show the condition and the reliability of the transformer more clearly, so as to reduce the distractions and handling of the distractions. Research used two transformers which data were taken in 2014, 2015, and 2016 in order to know the performance trends to be able to evaluate the performance and reliability of the two transformers. The results obtained, the transformer in an acceptable or could be said good with the Performance Index of 60%, as seen from the results obtained then the actions that can be done is to increase the test/diagnose on both transformers.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | kegagalan transformator, key gas, health index, roger’s ratio, indeks performa. transformer failure, key gases, health index, roger's ratio, performance index. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 05 Dec 2025 07:37 |
| Last Modified: | 05 Dec 2025 07:37 |
| URI: | https://repository.itpln.ac.id/id/eprint/4441 |