Abstract

Transformator distribusi memiliki peran penting dalam sistem penyaluran tenaga listrik ke pelangan . Namun dalam operasionalnya, sering terjadi ketidakseimbangan beban antar fasa yang dapat menyebabkan kerugian daya dan menurunnya efisiensi transformator. Penelitian ini bertujuan untuk menganalisis pengaruh ketidakseimbangan beban terhdap arus, tegangan, daya, serta efisiensi transformator distribusi di PT.PLN (PERSERO) UP3 Jayapura. Metodepenelitian yang digunakan adalah kuantitatif dan kualitatif, dengan pengumpulan data primer berupa arus. Tegangan,resistansi, dan daya input/ outputdari trafo yang diamati. Data dianalisis secara matematis untuk menghitung besar ketidakseimbangan. Rugi rugi daya, dan efisiensi transformator. Hasil penelitian menunjukan bahwa ketidakseimbangan beban menyebabkan arus netral mengalir dan menimbulkan rugi-rugi daya yang signifikan.Semakin besar ketidakseimbangan semakin besar pula kerugian daya dan penurunan efisiensi yang terjadi, oleh karena itu. Diperlukan perencanaan dan pengelolaan beban yang optimalkan untuk menimalkan ketidakseimbangan guna meningkatan efisiensi distribusi tenaga listrik. Berdasarkan hasil analisis, transformator distribusi yang terdapat di PT PLN (Persero) UP3 Jayapura berada dalam kondisi tidak seimbang. Ketidakseimbangan ini ditunjukkan oleh perbedaan arus pada masing-masing fasa, baik pada beban siang maupun malam hari. Persentase ketidakseimbangan beban pada siang hari mencapai 36,00 %, sementara pada malam hari meningkat menjadi 42,19 %. Kondisi ini menandakan bahwa semakin besar perbedaan arus antar fasa, maka semakin tinggi pula tingkat ketidakseimbangan beban.Meskipun terdapat ketidakseimbangan beban, efisiensi transformator distribusi tetap tergolong tinggi, yakni sebesar 96,9 % pada saat beban siang. Hal ini menunjukkan bahwa efisiensi akan meningkat apabila selisih antara daya input dan output semakin kecil atau jika rugi-rugi daya dapat ditekan seminimal mungkin. Rugi-rugi daya yang terjadi berkaitan langsung dengan arus netral yang mengalir akibat ketidakseimbangan beban.

Distribution transformers have an important role in the system for distributing electric power to customers. However, in operation, load imbalances between phases often occur which can cause power losses and reduced transformer efficiency. This research aims to analyze the effect of load imbalance on current, voltage, power and distribution transformer efficiency at PT PLN (PERSERO) UP3 Jayapura. The research method used is quantitative and qualitative, with primary data collection in the form of current. The voltage, resistance and input/output power of the transformer are observed. The data is analyzed mathematically to calculate the size of the imbalance. Power losses and transformer efficiency. The research results show that load imbalance causes neutral current to flow and causes significant power losses. The greater the imbalance, the greater the power losses and reduced efficiency that occur, therefore. Optimized load planning and management is needed to minimize imbalances in order to increase the efficiency of electric power distribution. The results of the study indicate that load imbalance causes neutral current to flow and causes significant power losses. The greater the imbalance, the greater the power loss and the decrease in efficiency that occurs, therefore. Optimized load planning and management are needed to minimize imbalance in order to increase the efficiency of electric power distribution. Based on the analysis results, the distribution transformers at PT PLN (Persero) UP3 Jayapura are in an unbalanced condition. This imbalance is indicated by the difference in current in each phase, both during the day and night loads. The percentage of load imbalance during the day reaches 36.00%, while at night it increases to 42.19%. This condition indicates that the greater the difference in current between phases, the higher the level of load imbalance. Despite the load imbalance, the efficiency of the distribution transformer remains relatively high, which is 96.9% during the day load. This shows that efficiency will increase if the difference between input and output power issmaller orif power losses can be minimized. The power losses that occur are directly related to the neutral current that flows due to load imbalance.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformator distribusi, ketidakseimbangan beban, rugi daya, efisiensi, arus netra Distribution transformer, load imbalance, power loss, efficiency, neutral current
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 09 Dec 2025 00:51
Last Modified: 09 Dec 2025 00:51
URI: https://repository.itpln.ac.id/id/eprint/4484

Actions (login required)

View Item
View Item