Mubarak, Husnul and Hasanah, Aas Wasri (2025) ANALISIS PENURUNAN TAHANAN ISOLASI PADA TRANSFORMATOR TERHADAP KELEMBABAN DAN SUHU PADA GARDU BETON KDR076 PT. PLN UP3 CENGKARENG. Diploma thesis, ITPLN.
TA_Husnul Mubarak_202271001.pdf
Restricted to Registered users only
Download (22MB)
Abstract
Transformator merupakan komponen vital dalam sistem distribusi tenaga listrik yang berfungsi untuk mentransformasikan tegangan. Salah satu parameter penting dalam menjaga kinerja dan keandalan transformator adalah tahanan isolasi. Penurunan tahanan isolasi dapat menyebabkan gangguan bahkan kerusakan pada peralatan, yang berpotensi mengganggu kontinuitas suplai listrik. Penelitian ini bertujuan untuk menganalisis hubungan antara kelembaban dan suhu lingkungan terhadap penurunan nilai tahanan isolasi pada transformator yang terpasang di Gardu Beton KDR076 PT. PLN UP3 Cengkareng. pengukuran langsung terhadap nilai tahanan isolasi transformator menggunakan insulation tester. Bahwa pengujian ini di lakukan pengukuran perbandingan antara nilai tahanan isolasi sebelum direvisi dan setelah di lakukan revisi yang di akibatkan penurunan nilai tahanan isolasi dengan standar isolasi 2 ohm. Semakin tinggi tingkat kelembaban dan suhu, maka semakin rendah nilai tahanan isolasi yang terukur. Temuan ini mengindikasikan pentingnya pengendalian kondisi lingkungan gardu untuk menjaga performa dan keandalan isolasi transformator. Penelitian ini diharapkan dapat menjadi acuan dalam perawatan preventif dan monitoring transformator di lingkungan tropis dengan kelembaban tinggi. Hasil analisis menunjukkan bahwa terdapat korelasi negatif antara kenaikan kelembaban dan suhu dengan nilai tahanan isolasi menunjukkan presentasi hasil pengukuran untuk perbandingan HV-LV, Rasio yang di dapatkan adalah 71,5%. Untuk HV-Ground, Rasionya 64,9%, dan untuk LV-Ground, Rasionya 69,1%.
Transformers are vital components in the electrical power distribution system that function to transform voltage. One important parameter in maintaining the performance and reliability of transformers is insulation resistance. A decrease in insulation resistance can cause interference or even damage to equipment, which has the potential to disrupt the continuity of electricity supply. This study aims to analyze the relationship between humidity and environmental temperature on the decrease in insulation resistance value in transformers installed in the KDR076 Concrete Substation of PT. PLN UP3 Cengkareng. Direct measurement of the transformer insulation resistance value using an insulation tester. This test was carried out by comparing the insulation resistance value before and after the revision, which resulted in a decrease in the insulation resistance value with the 2 ohm insulation standard. The higher the humidity and temperature levels, the lower the measured insulation resistance value. This finding indicates the importance of controlling the substation environmental conditions to maintain the performance and reliability of transformer insulation. This study is expected to be a reference in preventive maintenance and monitoring of transformers in tropical environments with high humidity. The results of the analysis show that there is a negative correlation between increases in humidity and temperature with insulation resistance values. Shows the presentation of measurement results for the HV-LV comparison, the ratio obtained is 71,5% for HV-Ground, the Ratio is 64,9%, and for LV-Ground, the ratio is 69,1%.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformator, Tahanan isolasi, kelembaban, suhu dan gardu beton. Transformer, insulation resistance, humidity, temperature and concrete substation |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 09 Dec 2025 01:09 |
| Last Modified: | 09 Dec 2025 01:09 |
| URI: | https://repository.itpln.ac.id/id/eprint/4486 |