FIRMANSYAH, IQBAL and Basri, Hasan (2015) UPAYA MENGATASI JATUH TEGANGAN PADA SALURAN DISTRIBUSI TEGANGAN RENDAH PT PLN (PERSERO) DISTRIBUSI JABAR DAN BANTEN AREA CIREBON KOTA. Diploma thesis, ITPLN.
SKRIPSI IQBAL FIRMANSYAH ( 2010-11-136).pdf
Restricted to Registered users only
Download (3MB)
Abstract
Dalam penyaluran tenaga listrik dari sumber tenaga listrik ke konsumen yang letaknya berjauhan selalu mengalami terjadinya kerugian berupa rugi – rugi daya sehingga menyebabkan terjadinya jatuh tegangan yang cukup besar yang mengakibatkan rendahnya tegangan terima terutama yang berbeda di ujung saluran.Tegangan pada jaringan tegangan rendah yang di tetapkan di sistem tenaga listrik oleh PT.PLN (Persero) adalah 230 Volt / 400 Volt. Di dalam operasinya tegangan pada sistem distribusi harus selalu di jaga agar tetap memenuhi standar tegangan operasi yaitu 0.9 Vnom ≤ Vop ≤ 1.05 Vnom. Untuk sistem 230 Volt / 400 Volt maka tegangan operasi fasa – netral harus dijaga selalu pada nilai 198 Volt ≤ Vop ≤ 231 Volt. Pada kenyataan nya di lapangan banyak tegangan, terutama pada ujung – ujung jaringan tegangan kurang dari 198 Volt (dari standar), untuk itu perlu perbaikan tegangan pada JTR tersebut. Perbaikan tegangan pada distribusi tegangan rendah dapat dilaksanakan dengan memasang gardu sisipan, mengganti penampang kawat penghantar dengan penampang kawat yang lebih besar, memperbaiki sambungan kawat penghantar di titik penyambungan, sadapan tanpa beban, dan pemakaian kapasitor (shunt).
In the distribution of electricity from the power source to the consumer that far apart always suffered losses in the form of loss - loss of power loss and voltage that results in a voltage drop large enough to result in low voltage thank particularly different at the end of the channel. The voltage on the low voltage network in the set of electric power system by PT PLN (Persero) is a 230 Volt / 400 Volt. In the operating voltage on the distribution system must be keep it meet that standard operating voltage Vop 0.9 ≤ Vnom ≤ 1.05 Vnom. For system 230 Volt / 400 Volt, the operating voltage phase - neutral must be kept constantly on the value of 198 Volts ≤ Vop ≤ 231 Volts. In fact its on the field much stress, especially at the end - the end of the voltage network under of 198 volts (standard), it is necessary to repair the voltage on the JTR. Repair the voltage on the low voltage distribution substations can be implemented by installing inserts, replacing the wire conductor cross section with a larger cross section of the wire, fix the conductor wire connection at the connection point, leads without load, and the use of capacitors (shunt).
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Jaringan Tegangan Rendah, Jatuh Tegangan, Vnominal Low Voltage Networks, Drop Voltage, Vnominal |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 21 Dec 2025 12:34 |
| Last Modified: | 21 Dec 2025 12:34 |
| URI: | https://repository.itpln.ac.id/id/eprint/4705 |