LODARMASE, PHILIPUS AMRY and Basri, Hasan (2015) EVALUASI PROTEKSI JARINGAN TEGANGAN MENENGAH 20 KV DI KOTA AMBON. Diploma thesis, ITPLN.
PHILIPUS AMRY LODARMASE.pdf
Restricted to Registered users only
Download (660kB)
Abstract
Keandalan sistem tenaga listrik dari pembangkitan sampai dengan distribusi sangat diperlukanbaik oleh pelanggan atau pemasok tenaga listrik dalam hal ini PLN. Gangguan yang terjadi sering dialami oleh jaringan yang terpasang di alam terbuka. Gangguan ini diakibatkan oleh petir, binatang, dan pohon yang terkena pada jaringan tenaga listrik, dan dapat menimbulkan gangguan satu fasa – tanah, dua fasa dan tiga fasa, akibatnya penyaluran tenaga listrik terganggu atau mengalami pemadaman. Sebagai pengaman dari gangguan tersebut dipasang sistem proteksi mulai dari sistem distribusi, seperti rele arus lebih untuk mengamankan gangguan fasa – fasa atau tiga fasa. Dan rele gangguan tanah untuk mengamankan gangguan fasa tanah. Rele arus lebih (OCR) dan rele gangguan tanah (GFR) yang dipasang pada penyulang masuk atau penyulang keluar, harus di setting sesuai perhitungan arus gangguan yang akan terjadi jika terjadi gangguan di penyulang keluar maka rele pada penyulang keluar saja yang trip (bekerja)
Power system reliability of generation and distribution of highly diperlukanbaik by customers or suppliers of electric power in this case PLN. Disturbance is often experienced by the network installed in the open. This disorder is caused by lightning, animals, and trees are exposed to the electric power network, and may interfere with one phase - land, two phase and three phase, as a result of electrical power is interrupted or experiencing blackouts. As the safety of the interference protection system installed from the distribution system, such as overcurrent relays to secure the phase disorder - phase or three phase. And ground fault relay to secure the land phase disorder. Overcurrent relay (OCR) and relay ground fault (GFR) mounted on the incoming feeder or feeders out, must be in the appropriate setting of fault current calculations that would occur if there is interference in the feeder out the relay on the feeders out only the trip (work)
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Sistem Pengaman (proteksi),jenis pengaman, rele OCR dan GFR. System Security (protection), type the security, OCR and GFR relay. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 21 Dec 2025 13:14 |
| Last Modified: | 21 Dec 2025 13:14 |
| URI: | https://repository.itpln.ac.id/id/eprint/4709 |