SYAHTIYAR, YUSUF and Rosid, Rosid (2015) PENGARUH IMPULS PETIR PADA ELEKTRODA YANG DI PASANG PARALEL TERHADAP PERMUKAAN TANAH. Diploma thesis, ITPLN.
cover.pdf
Download (16kB)
awal.pdf
Download (233kB)
bab 1 -bab 5.pdf
Restricted to Registered users only
Download (1MB)
Abstract
Di Saluran Udara Tegangan Tinggi diperlukan sistem pembumian dengan tujuan sebagai sarana untuk mengalirkan arus gangguan ke dalam tanah, baik dalam kondisi normal maupun kondisi gangguan, tanpa melebihi batas – batas operasi dan kemampuan peralatan untuk dapat menjamin agar orang yang berada disekitar instalasi listrik yang ditanahkan tidak mengalami kejut listrik yang membahayakan. Sistem pembumian yang paling mudah adalah sistem pembumian menggunakan elektroda batang. Nilai tahanan pembumian antara lain bergantung kepada nilai tahanan jenis tanah. Nilai tahanan pembumian (grounding) ada dua macam, yaitu tahanan pembumian frekuensi 50 Hz dan tahanan pembumian impuls. Tahanan pembumian impuls selain bergantung kepada tahanan jenis tanah, juga bergantung kepada bentuk gelombang impuls (kecuramannya). Arus gangguan impuls dapat berupa impuls petir atau impuls pensaklaran (switching) impuls. Impedansi impuls adalah rasio dari nilai tegangan dan arus puncak yang mungkin diterima sistem pembumian disaat terjadinya arus impuls. Impedansi impuls pada elektroda adalah rasio antara nilai sesaat dari tegangan pada tanah dan arus yang mengalir pada elektroda yang terjadi gangguan. Dalam tulisan ini akan dikaji pengaruh impuls pada tahanan pembumian elektroda batang yang dipasang paralel terhadap permukaan tanah.
In the High Voltage Transmission Line required earthing system with the purpose as a means to drain into the ground fault current, both under normal conditions and fault conditions, without exceeding the range of operation and the ability of the equipment to be able to ensure that people who are around are not grounded electrical installation experienced a dangerous electric shock. Earthing system is the easiest to use system earthing electrode rod. Earthing resistance value among others depends on the type of soil resistivity values. Values of the resistance earthing (grounding) are of two kinds, namely the frequency of 50 Hz grounding resistance and impulse grounding resistance. Impulse grounding resistance in addition depends on the soil resistivity, also depends on the shape of the wave impulse (curve). Impulse fault current can be a lightning impulse or impulse switching. Impulse impedance defined as the ratio of the peak value of the voltage and current grounding system which may be accepted when an electrical impulse. Impulse impedance of ground electrode defined as the ratio of the instantaneous values of the total ground voltage and of the current flowing from the electrode at the feeding point. In this paper studied the effect of lightning impulses on the electrode is installed parallel to the ground.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Tahanan Pembumian, Arus Gangguan , Impedansi Impuls Earthing Resistance, Fault Current, Impulse Impedancea |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 22 Dec 2025 02:38 |
| Last Modified: | 22 Dec 2025 02:38 |
| URI: | https://repository.itpln.ac.id/id/eprint/4718 |