KAJIAN PENGGUNAAN CIRCUIT BREAKER OUTGOING DI TENGAH PENYULANG VOLUME DI PLN UP3 PONDOK KOPI

SITUMEANG, WIRA SONYIA and Koerniawan, Tony (2019) KAJIAN PENGGUNAAN CIRCUIT BREAKER OUTGOING DI TENGAH PENYULANG VOLUME DI PLN UP3 PONDOK KOPI. Diploma thesis, ITPLN.

[thumbnail of WIRA SONYIA SITUMEANG 201671184.pdf] Text
WIRA SONYIA SITUMEANG 201671184.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Pemadaman merupakan hal yang merugikan baik untuk pelanggan maupun PT. PLN (Persero) itu sendiri. CBO (Circuit Breaker Outgoing) berfungsi sebagai pemutus beban ketika terjadi gangguan arus hubung singkat dimana ketika terjadi gangguan maka relay pada CBO akan mengirim sinyal ke PMT untuk trip. Di PT. PLN (Persero) UP3 Pondok Kopi dapat dilihat dampak pengunaaan circuit breaker outgoing pada penyulang Volume. Pemasangan CBO efisien untuk mengurangi daerah pemadaman.Hal ini terlihat dari hasil perghitungan ENS (Energy Not Supplied) pada penyulang Volume. Pada saat gangguan sebelum menggunakan CBO mengakibatkan padam satu penyulang yang terdiri dari 15 gardu. Hasil perhitungan ENS pada saat gangguan sebelum menggunakan CBO adalah 18331,395 kWH. Sedangkan pada saat gangguan setelah menggunakan CBO mengakibatkan padam 8 gardu dari 15 gardu pada penyulang Volume. Hasil perhitungan ENS (Energi Not Supplied) pada saat gangguan ini adalah 5546,864 kWH. Berdasarkan hasil perhitungan sebelum dan sesudah menggunakan CBO dapat diketahui efisiennya CBO dalam mengurangi energi yang
tidak tersalurkan.

Blackout is a disadvantage both for the customer and PT PLN (Persero) itself. CBO (circuit Breaker Outgoing) serves as a breaker of disruption load when the current short circuited where when a disturbance then relay on CBO will send a signal to the breakers to power trip. in the electricity transmission system and losses on the part of consumers of electrical energy. IN PT.PLN (Persero) UP3 Pondok Kopi can be seen the impact of the use vircuit breaker in Volume feeders.Using circuit breaker to lessen thr area of the
extingguishing. This can be ssen from the result of energy not supplied in Volume feeders. In the resulting in interference before using circuit breaker shut down one feeders consisting of fifteen substation. The results of energy not supplied before using CBO is 18331,395 kWH. While at the time of disorder after using circuit breaker resulting in exttinguished 8 substastion than 15 substation on Volume feeders. The result of reckoning ENS at the time of these disorders is 5546,864 kWH. Based on the calculation on before and after use CBO it can be seen the inefficiency of the CBO in reducing energy not supplied.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Circuit Breaker Outgoing, Energy Not Supplied. Circuit Breaker Outgoing, Energy Not Supplied.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 11 Feb 2026 04:56
Last Modified: 11 Feb 2026 14:35
URI: https://repository.itpln.ac.id/id/eprint/4976